Troubleshooting
6- 46
TLA5000 Series Service Manual
3.
There is a warning that the contents of your hard disk will be destroyed if
you choose to continue. Click Yes to continue the process.
4.
The program will automatically start and guide you through the rest of the
procedure. The image loading procedure is fully automatic and takes
approximately 15 minutes to complete.
The image loading procedure automatically installs and sets up the logic
analyzer application. You do not need to make any changes to the setup to
use the logic analyzer. When prompted, remove Disc 1 and insert Disc 2.
5.
After the image is loaded, remove the CD from the CD drive and reboot the
logic analyzer.
6.
The Systems Settings Change error message displays, prompting you to
restart the instrument before your changes can take effect. Click Yes to
restart the instrument.
7.
Reinstall any user files that you backed up previously. Reinstall any other
software (such as the microprocessor support packages) that the customer
purchased and may want to use on the logic analyzer.
NOTE
. Before reinstalling the TLA Application software, check to see if any
operating system patches need to be installed.
Reinstalling the TLA Application Software
Complete the following steps to reinstall the latest version of the TLA applica-
tion software without reinstalling the operating system software. Use these steps
as a first resort to recovering from application software problems. If you still
experience problems with the software after completing these steps, follow the
instructions under
Restoring the Hard Disk Image
beginning on page 6--44.
While using this procedure you will be asked to log on as Administrator. The
logic analyzer is initially set up to automatically log on as Administrator (with
no password) so you may not see the login prompt. If the network setups have
been changed on the instrument, make sure that you log on as Administrator or
as a user who has administrator privileges. Failure to do so can prevent the
software upgrade from completing successfully.
1.
Log on to the instrument as Administrator and quit any applications.
2.
Install Disc 1 of the Tektronix Logic Analyzer Family Application Software
in the CD-ROM drive of the logic analyzer.
3.
Click Run in the Windows Start menu to display the Run dialog box.
Содержание TLA5201
Страница 5: ......
Страница 13: ...Table of Contents viii TLA5000 Series Service Manual...
Страница 17: ...Service Safety Summary xii TLA5000 Series Service Manual...
Страница 21: ...Preface xvi TLA5000 Series Service Manual...
Страница 27: ...Specifications 1 2 TLA5000 Series Service Manual...
Страница 35: ...Operating Information 2 8 TLA5000 Series Service Manual...
Страница 51: ...Performance Verification 4 12 TLA5000 Series Service Manual Figure 4 3 TLACAL1 test fixture connections...
Страница 61: ...Performance Verification 4 22 TLA5000 Series Service Manual...
Страница 65: ...Adjustment Procedures 5 4 TLA5000 Series Service Manual Figure 5 1 TLACAL2 test fixture connections...
Страница 73: ...Maintenance 6 4 TLA5000 Series Service Manual...
Страница 105: ...Removal and Installation Procedures 6 36 TLA5000 Series Service Manual...
Страница 119: ...Repackaging Instructions 6 50 TLA5000 Series Service Manual...
Страница 121: ...Options 7 2 TLA5000 Series Service Manual...
Страница 123: ...Electrical Parts List 8 2 TLA5000 Series Service Manual...
Страница 125: ...Diagrams 9 2 TLA5000 Series Service Manual...
Страница 132: ...Mechanical Parts List TLA5000 Series Service Manual 10 7 1 2 3 4 2 Figure 10 2 Inner panels...
Страница 136: ...Mechanical Parts List TLA5000 Series Service Manual 10 11...
Страница 138: ...Mechanical Parts List TLA5000 Series Service Manual 10 13 1 2 3 4 5 6 7 8 3 11 8 9 10 11 12 13 14 Figure 10 4 Drives...
Страница 140: ...Mechanical Parts List TLA5000 Series Service Manual 10 15 1 2 3 3 3 4 5 2 Figure 10 5 Acquisition assembly...