How to install and con
fi
gure Option DPW
How to install and con
fi
gure Option DPW
This section provides the following information on how to install the Option DPW
backup Power Supply module into the SPG700 generator:
Guidelines for preventing component damage
Instructions for installing or replacing the Power Supply module
Instructions for how to con
fi
gure the preferred (active) supply
Required equipment
No equipment is required to install the backup Power Supply module.
How to prevent component damage
CAUTION.
Electrostatic discharge (ESD) can damage components on the modules
and mainframe. To prevent ESD or other component damage, follow the steps
below when installing, removing, or handling modules:
Wear a grounded antistatic wrist strap to discharge the static voltage from
your body while installing or removing modules from the mainframe.
Transport and store modules in a static-protected bag or container.
Do not slide the module over any surface.
Handle modules as little as possible.
Do not touch module components or connector pins.
Do not use any devices capable of generating or holding a static charge in the
work area where you remove, install, or handle modules.
Avoid handling modules in areas that have a
fl
oor or work-surface covering
capable of generating a static charge.
8
SPG70UP Field Upgrade Instructions