Compliance Information

Safety Compliance

EC Declaration of Conformity – Low Voltage

Compliance was demonstrated to the following speci

fi

cation as listed in the Of

fi

cial Journal of the European Communities:

Low Voltage Directive 2006/95/EC.

EN 61010-1: 2001. Safety requirements for electrical equipment for measurement control and laboratory use.

U.S. Nationally Recognized Testing Laboratory Listing

UL 61010-1:2004, 2

nd

Edition. Standard for electrical measuring and test equipment.

Canadian Certi

fi

cation

CAN/CSA-C22.2 No. 61010-1:2004. Safety requirements for electrical equipment for measurement, control, and

laboratory use. Part 1.

Additional Compliances

IEC 61010-1: 2001. Safety requirements for electrical equipment for measurement, control, and laboratory use.

Equipment Type

Test and measuring equipment.

Safety Class

Class 1 – grounded product.

Pollution Degree Description

A measure of the contaminants that could occur in the environment around and within a product. Typically the internal
environment inside a product is considered to be the same as the external. Products should be used only in the environment
for which they are rated.

Pollution Degree 1. No pollution or only dry, nonconductive pollution occurs. Products in this category are generally

encapsulated, hermetically sealed, or located in clean rooms.

Pollution Degree 2. Normally only dry, nonconductive pollution occurs. Occasionally a temporary conductivity that is

caused by condensation must be expected. This location is a typical of

fi

ce/home environment. Temporary condensation

occurs only when the product is out of service.

Pollution Degree 3. Conductive pollution, or dry, nonconductive pollution that becomes conductive due to condensation.

These are sheltered locations where neither temperature nor humidity is controlled. The area is protected from direct
sunshine, rain, or direct wind.

Pollution Degree 4. Pollution that generates persistent conductivity through conductive dust, rain, or snow. Typical

outdoor locations.

PWS2185, PWS2323, PWS2326, and PWS2721 User Manual

vii

Содержание PWS2185

Страница 1: ...PWS2185 PWS2323 PWS2326 and PWS2721 Linear DC Power Supplies ZZZ User Manual P071275100 071 2751 00 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...

Страница 2: ......

Страница 3: ...PWS2185 PWS2323 PWS2326 and PWS2721 Linear DC Power Supplies ZZZ User Manual xx...

Страница 4: ...d by national copyright laws and international treaty provisions Tektronix products are covered by U S and foreign patents issued and pending Information in this publication supersedes that in all pre...

Страница 5: ...tomer shall be responsible for paying all shipping charges duties taxes and any other charges for products returned to any other locations This warranty shall not apply to any defect failure or damage...

Страница 6: ......

Страница 7: ...siderations ix Preface x Key Features x Getting Started 1 Standard Accessories 1 Options and Optional Accessories 1 Specifications 2 Operating Requirements 2 Installing the System 3 Cleaning 6 Operati...

Страница 8: ...Table of Contents ii PWS2185 PWS2323 PWS2326 and PWS2721 User Manual...

Страница 9: ...gs To avoid fire or shock hazard observe all ratings and markings on the product Consult the product manual for further ratings information before making connections to the product Power disconnect Th...

Страница 10: ...uld result in damage to this product or other property Symbols and Terms on the Product These terms may appear on the product DANGER indicates an injury hazard immediately accessible as you read the m...

Страница 11: ...and interruptions immunity 4 EN 61000 3 2 2006 AC power line harmonic emissions EN 61000 3 3 1995 Voltage changes fluctuations and flicker European contact Tektronix UK Ltd Western Peninsula Western...

Страница 12: ...unications Act per the following standard in accordance with ACMA CISPR 11 2003 Radiated and Conducted Emissions Group 1 Class A in accordance with EN 61326 1 2006 Australia New Zealand contact Baker...

Страница 13: ...n the environment around and within a product Typically the internal environment inside a product is considered to be the same as the external Products should be used only in the environment for which...

Страница 14: ...nt Category IV For measurements performed at the source of low voltage installation Measurement Category III For measurements performed in the building installation Measurement Category II For measure...

Страница 15: ...the environment and to reduce the use of natural resources we encourage you to recycle this product in an appropriate system that will ensure that most of the materials are reused or recycled appropri...

Страница 16: ...cy 0 2 Basic current accuracy Less than 3 mVpp ripple and noise 20 user defined setup memories Model Description PWS2185 DC power supply 18 V 5 A 1 channel PWS2323 DC power supply 32 V 3 A 1 channel P...

Страница 17: ...tains detailed information about the instrument including specifications and how to verify performance 077 0482 XX One of the following North America Option A0 The factory sets the 110V 220V selector...

Страница 18: ...ing Altitude Operating 100 capability up to 2 000 meters Pollution Degree 2 For indoor use only Nominal Voltage Ratings There are two ranges for all models selectable by the line voltage selector swit...

Страница 19: ...operating at or above 1000 volts no conductive part of the circuit may be exposed WARNING Use properly rated load wires All load wires must be heavy enough not to overheat when carrying the maximum sh...

Страница 20: ...er supply First check that the AC power cord is firmly plugged into the power connector on the rear panel of the power supply You should also make sure that the AC power source you plugged the power s...

Страница 21: ...ndicated on the front panel of the unit 9 Check if the displayed voltage value is approximately the same value as the voltage setting Current output check To verify the basic current functions with a...

Страница 22: ...an the exterior surface perform the following steps 1 Remove loose dust on the outside of the power supply with a lint free cloth Use care to avoid scratching the display 2 Use a soft cloth dampened w...

Страница 23: ...d Recall function buttons 5 Number keys 0 to 9 and Esc for direct numeric entry 6 V Set I Set Menu and Output On Off function buttons 7 Power button Function button descriptions Button Description Set...

Страница 24: ...d then press the Enter button Max Volt Sets the maximum output voltage value to which you can set the instrument Key Lock When activated this feature locks the front panel controls and prompts for a p...

Страница 25: ...r The Volt meter display is active Lock Front panel controls are locked Enter password to unlock Rear Panel at a Glance 1 Cooling vents 2 110 V 220 V power connector 3 Factory test port CAUTION Unauth...

Страница 26: ...rom Set mode to Meter mode if you do not press any key for 3 seconds You can enable or disable the output of the power supply from the front panel by pushing the Output On Off button When the output i...

Страница 27: ...nstant voltage mode If the CC message appears the instrument is operating in constant current mode Crossover from the constant current mode to the constant voltage mode also occurs automatically in re...

Страница 28: ...Saving setups 1 After you set up the power supply voltage limit current limit and the maximum output voltage push the Save button 2 Use the number keys or the arrow keys to select the setup memory 1 t...

Страница 29: ...on To enable or disable this control 1 Push the Menu 2 Use the down arrow key to select OUT RECALL 3 Push Enter 4 Use the up arrow key to select On or Off 5 Push Enter 6 Push Esc to exit the menu syst...

Страница 30: ...any button or press any key To enable or disable this feature 1 Push Menu 2 Use the down arrow key to select Key Beep 3 Push Enter 4 Use the arrow keys to select On or Off 5 Push Enter 6 Push Esc to...

Страница 31: ...and Recall 7 Key Beep 14 M Max Volt Set 12 Menu button 8 Messages 8 N No power 4 O On off button 8 Operating requirements 2 Operation current limit adjustment 12 recalling setups 12 saving setups 12 v...

Отзывы: