![Tektronix P7330 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/tektronix/p7330/p7330_user-manual_1077390031.webp)
P7330 3.5 GHz Differential Probe User Manual
21
Appendix A: Specifications
The specifications in Tables 3 through 6 apply to a P7330 probe
installed on a TDS7404 oscilloscope. The probe must have a
warm-up period of at least 20 minutes and be in an environment that
does not exceed the limits described in Table 3. Specifications for the
P7330 differential probe fall into three categories: warranted, typical,
and nominal characteristics.
Warranted Characteristics
Warranted characteristics (Table 3) describe guaranteed performance
within tolerance limits or certain type-tested requirements.
Warranted characteristics that have checks in the
Performance
Verification
section are marked with the
n
symbol.
Table 3: Warranted electrical characteristics
Characteristic
Description
n
Rise time (probe only)
140 ps (130 ps typical)
n
DC gain
0.2
±
2%
n
Output offset voltage
±
10 mV +20
_
C to +30
_
C
(+68
_
F to +86
_
F)
±
50 mV displayed on screen with
TekConnect interface
Maximum nondestructive input voltage
±
15 V(DC + peak AC) between signal and
common of the same channel.
Delay variation (probe-to-probe)
600 ps maximum
Temperature
Operating: 0 to +40
_
C
(+32 to +104
_
F)
Nonoperating: --55 to +75
_
C
(--131 to +167
_
F)
1
Содержание P7330
Страница 4: ......
Страница 48: ...Appendix C Replaceable Parts P7330 3 5 GHz Differential Probe User Manual 38...