Designing an Interface Between a P6434 Probe and a Target System
28
P6434 Probe Instructions
The low-profile extender used with the P6434 probe increases the load. The
additional load is equivalent to a 100
Ω
resistor connected in series with
approximately three inches of 75
Ω
coaxial cable to the probe tip.
Although the extender can increase the loading significantly, using the extender
might be necessary in situations where there is as little as half an inch of
clearance.
The extender is useful in a target system where signal risetimes are greater than
one or two nanoseconds. Faster risetimes cause transmission line reflections on
signals.
Figure 20 shows the equivalent circuit for the P6434 probe with a low-profile
extender
1.6 nH
1.6 nH
0.7 pF
0.005
Ω
0.005
Ω
100
Ω
Length = 3 in
0.005
Ω
1.6 nH
0.7pF
0.005
Ω
1.1 pF
20 k
Ω
0.23 pF
Length = 58 in
LOSSY
+2.2 V
LOSSY
1.6 nH
75
Ω
Mictor connector equivalent circuit
Mictor connector equivalent circuit
Figure 20: Equivalent circuit for the P6434 probe with a low-profile extender