Speci
fi
cations
Read the caution below if you are using the probe with the
TPS2000 series oscilloscope input set to AC coupling.
CAUTION.
When the oscilloscope input is set to AC
Coupling, do not probe DC levels >300 V or AC signals
less than 1 Hz and >300 V
RMS
. (See graph below.)
Refer to the reference lead derating curve below when
making
fl
oating measurements.
Table 2: Electrical and mechanical speci
fi
cations
Characteristic
Speci
fi
cation
Bandwidth
DC to 200 MHz (–3 dB)
System attenuation accuracy
100:1
Compensation range
10 pF–25 pF
System input resistance
100 M
Ω
System input capacitance
4.6 pF
Maximum tip input voltage
1000 V CAT II
Characteristic
Speci
fi
cation
Maximum reference lead
voltage to ground
600 V CAT II
Cable length
1.2 m
Table 3: Environmental speci
fi
cations
Characteristics
Description
Temperature
Maximum operating
Minimum operating
Nonoperating
+40 °C (+104 °F)
+5 °C (+40 °F)
–55 °C to +75 °C (–67 °F to
+167 °F)
Humidity
80% up to +30 °C (+86 °F), falling
linearly to 50% at +40 °C (+104 °F)
Altitude
Operating
Nonoperating
2.0 km (6,600 ft) maximum
15 km (50,000 ft) maximum
Table 4: Certi
fi
cations and compliances
Characteristics Description
EC
Declaration
of
Conformity
Compliance was demonstrated to the following
speci
fi
cation as listed in the Of
fi
cial Journal of
the European Communities:
Low Voltage Directive 2006/95/EC:
EN61010-031: 2002
Category
Examples of Products in this
Category
CAT III
Distribution-level mains,
fi
xed
installation
CAT II
Local-level mains, appliances,
portable equipment
Measurement
Category
Descriptions
CAT I
Circuits not directly connected to
mains.
Pollution
Degree 2
Do not operate in environments where cond–
uctive pollutants may be present (as de
fi
ned in
IEC 61010-1). Rated for indoor use only.
Additional
Safety
Standards
UL61010B-1, First Edition & UL61010B-2-031,
First Edition.
CAN/CSA-C22.2 No. 1010.1-92, &
CAN/CSA-C22.2 No. 1010.2.031-94
IEC61010-031:2002
Equipment Recycling.
This product complies
with the European Union’s requirements
according to Directive 2002/96/EC on waste
electrical and electronic equipment (WEEE). For
more information about recycling options, check
the Support/Service section of the Tektronix
Web site (www.tektronix.com).
Safety Summary
Review the following safety precautions to avoid injury and
prevent damage to this product or any products connected
to it. To avoid potential hazards, use this product only as
speci
fi
ed. Using the probe or accessories in a manner not
speci
fi
ed could result in a shock or
fi
re hazard.
To Avoid Fire or Personal Injury
For Use With TPS2000 and THS3000 Series Oscilloscopes
Only.
Do not
fl
oat the reference lead of this probe above the
rated
fl
oat voltage (600 V RMS CAT II).
Connect and Disconnect Properly.
Connect the probe output
to the measurement instrument before connecting the probe
to the circuit under test. Disconnect the probe input and
the probe reference lead from the circuit under test before
disconnecting the probe from the measurement instrument.
Avoid Electric Shock.
To avoid injury or loss of life, do not
connect or disconnect probes or test leads while they are
connected to a voltage source.
Observe All Terminal Ratings.
To avoid
fi
re or shock hazard,
observe all ratings and markings on the product. Consult
the product manual for further ratings information before
making connections to the product.
Avoid Electric Shock.
When using probe accessories, never
exceed the lowest rating of the probe or its accessory,
whichever is less, including the measurement category and
voltage rating.
Avoid Electric Overload.
To avoid injury or
fi
re hazard, do
not apply potential to any input, including the reference
inputs, that varies from ground by more than the maximum
rating for that input.
Avoid Exposed Circuitry and Do not Operate Without
Covers.
Do not touch exposed connections and components
when power is present.
Inspect The Probe And Accessories.
Before each use,
inspect probe and accessories for damage (cuts, tears,
defects in the probe body, accessories, cable jacket, etc.).
Do not use if damaged.
Do Not Operate in Wet/Damp Conditions.
Do Not Operate in an Explosive Atmosphere.
Keep Product Surfaces Clean and Dry.
Safety Terms and Symbols Terms in This Manual.
These terms may appear in this manual:
WARNING.
Warning statements identify conditions or
practices that could result in injury or loss of life.
CAUTION.
Caution statements identify conditions or
practices that could result in damage to this product or
other property.
Symbols on the Product.
These symbols may appear on
the product:
Contacting Tektronix
Web site:
www.tektronix.com
Phone:
1-800-833-9200
Address:
Tektronix, Inc.
Department or name (if known)
14200 SW Karl Braun Drive
P.O. Box 500
Beaverton, OR 97077
USA
Email:
Warranty Information
For warranty information, go to
www.tektronix.com/warranty
Copyright © Tektronix, Inc. All rights reserved.
www.tektronix.com