Safety precautions

The following safety precautions should be observed before using this product and any 

associated instrumentation. Although some instruments and accessories would normally be 

used with nonhazardous voltages, there are situations where hazardous conditions may be 

present. 
This product is intended for use by personnel who recognize shock hazards and are familiar 

with the safety precautions required to avoid possible injury. Read and follow all installation, 

operation, and maintenance information carefully before using the product. Refer to the user 

documentation for complete product speci

 cations. 

If the product is used in a manner not speci

 ed, the protection provided by the product 

warranty may be impaired. 
The types of product users are: 

Responsible body

 is the individual or group responsible for the use and maintenance of  

equipment, for ensuring that the equipment is operated within its speci

 cations and operating 

limits, and for ensuring that operators are adequately trained. 

Operators

 use the product for its intended function. They must be trained in electrical safety 

procedures and proper use of the instrument. They must be protected from electric shock and 

contact with hazardous live circuits. 

Maintenance personnel

 perform routine procedures on the product to keep it operating 

properly, for example, setting the line voltage or replacing consumable materials. Maintenance 

procedures are described in the user documentation. The procedures explicitly state if the 

operator may perform them. Otherwise, they should be performed only by service personnel. 

Service personnel

 are trained to work on live circuits, perform safe installations, and 

repair products. Only properly trained service personnel may perform installation and 

service procedures. 
Keithley products are designed for use with electrical signals that are measurement, control, 

and data I/O connections, with low transient overvoltages, and must not be directly connected 

to mains voltage or to voltage sources with high transient overvoltages. Measurement 

Category II (as referenced in IEC 60664) connections require protection for high transient 

overvoltages often associated with local AC mains connections. Certain Keithley measuring 

instruments may be connected to mains. These instruments will be marked as category II 

or higher. 
Unless explicitly allowed in the speci

 cations, operating manual, and instrument labels, do 

not connect any instrument to mains. 
Exercise extreme caution when a shock hazard is present. Lethal voltage may be present on 

cable connector jacks or test 

 xtures. The American National Standards Institute (ANSI) 

states that a shock hazard exists when voltage levels greater than 30 V RMS, 42.4 V peak, 

or 60 VDC are present. A good safety practice is to expect that hazardous voltage is present 

in any unknown circuit before measuring. 
Operators of this product must be protected from electric shock at all times. The responsible 

body must ensure that operators are prevented access and/or insulated from every 

connection point. In some cases, connections must be exposed to potential human contact. 

Product operators in these circumstances must be trained to protect themselves from the risk 

of electric shock. If the circuit is capable of operating at or above 1000 V, no conductive part of 

the circuit may be exposed. 
Do not connect switching cards directly to unlimited power circuits. They are intended to be 

used with impedance-limited sources. NEVER connect switching cards directly to AC mains. 

When connecting sources to switching cards, install protective devices to limit fault current and 

voltage to the card. 
Before operating an instrument, ensure that the line cord is connected to a properly-grounded 

power receptacle. Inspect the connecting cables, test leads, and jumpers for possible wear, 

cracks, or breaks before each use. 
When installing equipment where access to the main power cord is restricted, such as rack 

mounting, a separate main input power disconnect device must be provided in close proximity 

to the equipment and within easy reach of the operator. 
For maximum safety, do not touch the product, test cables, or any other instruments while 

power is applied to the circuit under test. ALWAYS remove power from the entire test system 

and discharge any capacitors before: connecting or disconnecting cables or jumpers, 

installing or removing switching cards, or making internal changes, such as installing or 

removing jumpers. 

Содержание Keithley 2657A

Страница 1: ...Model 2657A High Power SourceMeter Instrument Quick Start Guide...

Страница 2: ...r high transient overvoltages often associated with local AC mains connections Certain Keithley measuring instruments may be connected to mains These instruments will be marked as category II or highe...

Страница 3: ...the associated information very carefully before performing the indicated procedure The CAUTION heading in the user documentation explains hazards that coulddamage the instrument Such damage may inva...

Страница 4: ...o 35 C Derate 3 relative humidity per C 35 C to 50 C Storage temperature 25 C to 65 C Pollution degree 1 or 2 CAUTION Carefully consider and configure the appropriate output off state source levels an...

Страница 5: ...cumentation for the 2657A instrument is available for download on the Keithley web page at tek com keithley Software for the 2657A instrument is also available for download from the Keithley web page...

Страница 6: ...he top of the box Packaging insert Rack mount hardware 2657A documentation and accessories 3 Remove the packaging insert 4 Carefully lift the 2657A instrument out of the box 5 Inspect the instrument f...

Страница 7: ...3 Interlock DB 25 male connector kit hardware 4 RJ45 LAN crossover cable 5 Power line cord Model 2657A Quick Start Guide not shown this document Safety supplement not shown Safety precautions not show...

Страница 8: ...e system For example if you are using a 500 V power supply with a 300 V dc rated switch the maximum allowed voltage in the system is 300 V dc Cover the device under test DUT to protect the operator fr...

Страница 9: ...strument so that it is easy to reach any disconnecting devices such as the power cord and the power switch Connect protective earth safety ground to the rear panel of the 2657A WARNING The ground wire...

Страница 10: ...on the doors of a test equipment rack The interlock line is pin 24 of the digital input output connector on the rear panel of the 2657A as shown in the following figure 1 14 13 25 DIGITAL I O Pin 22 5...

Страница 11: ...o access the circuit while hazardous voltages are present WARNING Connect the enclosure of all metal test fixtures to protective earth safety ground Nonconductive test fixtures must be rated to double...

Страница 12: ...outlet may result in personal injury or death due to electric shock WARNING Do not replace detachable mains supply cords with inadequately rated cords Failure to use properly rated cords may result in...

Страница 13: ...e When the instrument is turned on you should see A series of dots All segments of the display light A brief display showing KEITHLEY Model 2657A Other startup checks The entire power up process takes...

Страница 14: ...his test SRC key RANGE keys Navigation wheel LIMIT key MEAS key AUTO key OUTPUT ON OFF control Step 1 Set source function range and level 1 Press the SRC SRC key You will see a blinking character in t...

Страница 15: ...field 2 Press the UP range arrow once so that the 10s digit is displayed It is displayed as 01 0000mA 3 Use the cursor key to highlight the 1s digit 4 Press the navigation wheel to enter EDIT mode 5...

Страница 16: ...e output off by pressing the OUTPUT ON OFF OUTPUT ON OFF control OUTPUT ON OFF control The output indicator LED turns off NOTE These steps confirm basic functionality of your instrument Turn the instr...

Страница 17: ...657A output is already on You attempt to turn on or enable the 2657A output when the interlock is disabled To recover from this error properly enable the interlock using a safe test fixture and then t...

Страница 18: ...by U S and foreign patents issued and pending Information in this publication supersedes that in all previously published material Specfication and price change privileges reserved TEKTRONIX and TEK a...

Отзывы: