2268S-901-01 Rev. A / January 2015
Voltage Status Register Commands
Query Voltage Status Register Event
SCPI command:
[:]STATus[<channel>]:QUEStionable:VOLTage[:EVENt]?
Query Voltage Status Register Condition
SCPI command:
[:]STATus[<channel>]:QUEStionable:VOLTage:CONDition?
Enable Voltage Status Register
SCPI command:
[:]STATus[<channel>]:QUEStionable:VOLTage:ENABle <status-enable>
Query Format:
[:]STATus[<channel>]:QUEStionable:VOLTage:ENABle?
Set Voltage Status Positive Transition Filter
SCPI command:
[:]STATus[<channel>]:QUEStionable:VOLTage:PTRansition <status-enable>
Query Format:
[:]STATus[<channel>]:QUEStionable:VOLTage:PTRansition?
Set Voltage Status Negative Transition Filter
SCPI command:
[:]STATus[<channel>]:QUEStionable:VOLTage:NTRansition <status-enable>
Query Format:
[:]STATus[<channel>]:QUEStionable:VOLTage:NTRansition?