A-3
Installation Information
Installation Information
Changes to the Installation section of the Model 4000 Installation & Service manual
are as follows:
Initial Installation of the Model 4000-3
Refer to the Section 2 of this manual for initial installation of the Model 4000-3,
with the following exceptions:
■
Ignore the references to connecting the power supply for 110-volt operation.
The Jeta +5 Volt power supply will not run on 110 volts; therefore, the power
supply frame cannot be connected to a 110-volt source.
■
Ignore references to Pioneer power supply units. No Pioneer units have been
shipped with Model 4000-3 Switchers. Beware of swapping power supply
assemblies between switchers. The Model 4000-3 will not operate properly
with Pioneer or Todd +5 Volt supplies from other Model 4000, 3000, or 2200
Switchers.
NOTE:
For the Jeta +5 Volt power supply, the BYPASS/PROTECT jumper in the Model
4000-3 fan assembly should be set to the BYPASS position as described in the Section 2,
Installation, in this manual.