Commands Listed in Alphabetical Order
Syntax
DISplay:INTENSITy:WAVEform <NR1>
DISplay:INTENSITy:WAVEform?
Arguments
<NR1>
is the waveform intensity and ranges from 1 to 100 percent.
Examples
DISPLAY:INTENSITY:WAVEFORM?
might return
DISPLAY:INTEnsITY:WAVEFORM 60
as the intensity of the waveforms.
DISplay:PERSistence
Sets or returns the display persistence. This affects the display only.
NOTE.
When Persistence is set to In
fi
nite, it does not mean that the brightness
of any pixel should never decrease. The brightness of a pixel is proportionally
dependent on the ratio between its intensity (which does NOT decrease at In
fi
nite
Persistence) and the maximum value of intensity of any pixel on the screen. If a
particular pixel get hit less often than others, its brightness will decrease over
time. It will become less bright relative to the pixels that get hit often.
Group
Display
Syntax
DISplay:PERSistence {<NR3>|CLEAR|AUTO|MINImum|INFInite}
DISplay:PERSistence?
Arguments
<NR3>
speci
fi
es the time of the persistence.
CLEAR
resets the persist time count down and clears the display of acquired points.
INFInite
displays waveform points until a control change resets the acquisition
system. When persistence is set to in
fi
nite, it does not mean that the brightness
of any pixel should never decrease. The brightness of a pixel is proportionally
dependent on the ratio between its intensity, which does NOT decrease at in
fi
nite
persistence, and the maximum value of intensity of any pixel on the screen. Thus,
if a particular pixel gets hit less often than others, its brightness will decrease over
time. It will become less bright relative to the pixels that get hit often.
AUTO
speci
fi
es that the oscilloscope automatically determines the
best waveform persistence based on the value of waveform intensity
(DISPLAY:INTEnsITY:WAVEFORM)
MINImum
speci
fi
es that the waveform persistence is set to the minimum value
of 0.0E0.
2-166
MSO4000 and DPO4000 Series Programmer Manual
Содержание DPO4000 Series
Страница 2: ......
Страница 10: ...Table of Contents vi MSO4000 and DPO4000 Series Programmer Manual ...
Страница 23: ...Command Syntax MSO4000 and DPO4000 Series Programmer Manual 2 9 ...
Страница 24: ...Command Syntax 2 10 MSO4000 and DPO4000 Series Programmer Manual ...
Страница 84: ...Command Groups 2 70 MSO4000 and DPO4000 Series Programmer Manual ...
Страница 546: ...Commands Listed in Alphabetical Order 2 532 MSO4000 and DPO4000 Series Programmer Manual ...
Страница 564: ...Status and Events 3 18 MSO4000 and DPO4000 Series Programmer Manual ...
Страница 565: ...Appendix A Character Set MSO4000 and DPO4000 Series Programmer Manual A 1 ...
Страница 566: ...Appendix A Character Set A 2 MSO4000 and DPO4000 Series Programmer Manual ...
Страница 572: ...Appendix B Reserved Words B 6 MSO4000 and DPO4000 Series Programmer Manual ...