12. Adjust Input Capacitors (C3322
and C4322)
Set the VOLTS/CM switches of the Type CA
Unit to .05.
Apply a 1 kc Signal from the
Type 105 Square-Wave Generator to the Type
C A Plug-In, through the P52 cable, the 5XT
and capacitance standardizer. The capacitance
standardizer should be connected between the
P52 cable and the Type CA Unit with the 5XT
between the P52 cable and the capacitance
standardizer.
Attach the Type 105 to the A channel input
connector of the Type CA Unit and adjust
the Type 105 Output Amplitude fo r a deflection
o f approximately 3.5 cm on the oscilloscope’ s
c rt. Now adjust C3322 fo r Optimum flat top
on the waveform. Then connect the Type 105
to the B channel input connector of the Type
C A Unit and adjust C4322 for Optimum flat
top.
13. Adjust VOLTS/CM
Compensations
Maintain the same output frequency and
amplitude from the Type 105 Square-Wave
Generator as in Step 12. See the charts below
fo r the adjustments to each channel. Note:
When the .5 VOLTS/CM position is reached
the 5XT attenuator must be removed.
A Channel Adjustments
VO LTS /CM
Switch
Adj fo r Optimum
Square C orner
Adj fo r Optimum
F lat Top
.1
C3311C
C3311B
.2
C3312C
C3312B
.5
C3313C
C3313B
1
C3314C
C3314B
2
C3315C
C3315B
5
C3316C
C3316B
10
C3317C
C3317B
20
C3318C
C3318B
When the adjustments to A channel have been
completed connect the cable from the Type
105 to the B channel input connector and proceed
with the adjustments fo r this channel.
B Channel Adjustments
VO LTS /CM
Switch
Adj fo r Optimum
Square C orn er
Adj fo r Optimum
F lat Top
.1
C4311C
C4311B
.2
C4312C
C4312B
.5
C4313C
C4313B
1
C4314C
C4314B
2
C4315C
C4315B
5
C4316C
C4316B
10
C4317C
C4317B
20
C4318C
C4318B
14. H. F. Compensations
Set oscilloscope Controls as follows:
TIME/CM
.2 MICROSEC
Set plug-in
Controls
as
follows:
VOLTS/CM (A and B)
.1
MODE
B ONLY
Connect the Type 107 Square-Wave Gener
ator to the channel B input connector of the
Type CA
Unit, installing the Terminating
Resistor between the P52 cable and the plug-in
unit. Adjust the Approximate Amplitude control
on the Type 107 for 3 cm of vertical deflection
on the crt of the oscilloscope. Adjust the
Approximate Frequency control for an approxi
mate output frequency of 450 kc.
Now adjust L3364, L4374, L4362, L4372,
L4334 and L4354 for an Optimum square
corner with no overshoot on the square-wave
Signal.
Set the MODE switch of the Type CA Unit
to A O N LY and connect the Type 107, in the
same manner as above, to the A channel
vertical input connector. F or channel A adjust
L3362, L3372, L3354 and L3334 for an Optimum
square corner with no overshoot on the square-
wave Signal.
Note
When you are finished check to
see that the plugs in the coils are
all approximately the same depth
inside the coil form. If they aren't
readjust
until this condition is
obtained.
15. Frequency Response
The
oscilloscope Controls should
be
set
as
follows.
TRIGGERING
MODE
AC L F REJECT
TIME/CM
.1 MILLISEC
S TA B ILITY
full right (cw)