![Tektronix 516 series Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/tektronix/516-series/516-series_instruction-manual_1078919020.webp)
C I R C U I T
D E S C R I P T I O N
A block diagram of the Type 516 Oscilloscope is shown
in Fig. 4-1. In general, operation of the oscilloscope is as
follows:
The signal or signals to be displayed are applied to the
Vertical Amplifier through the A and/or B input connectors.
The Vertical Amplifier amplifies the signals and applies them
through the Delay Line to the vertical deflection plates of
the cathode-ray tube. A sample of the signal is taken out at
the Vertical Amplifier and applied to the Time-Base Trigger.
The Time-Base Trigger generates a trigger pulse which bears
a selected fixed time relationship to the incoming signal. This
trigger pulse triggers the Time-Base Generator which gen
erates a linear sawtooth waveform. The sawtooth waveform
is applied through the Horizontal Amplifier to deflect the crt
beam horizontally at a selected fixed rate. Provisions are
also made for generating trigger pulses which bear a selected
fixed time relationship to some external signal or to the ac
line waveform. If desired, the Time-Base Generator may be
disabled and an external signal applied directly to the Hori
zontal Amplifier. The Amplitude Calibrator provides an am
plitude-calibrated square wave for use in calibrating the
gain of the Vertical Amplifier and adjusting the compensa-
4-1
Fig. 4 -1 . Type 516 Oscilloscope block diagram .
Содержание 516 series
Страница 5: ... Type 516 ...
Страница 19: ...NOTES Type 516 ...
Страница 39: ...NOTES Type 516 ...
Страница 54: ...Type 516 SECTION 7 MECHANICAL PARTS LIST 7 1 ...
Страница 55: ... Mechanical Parts List Type 516 FRONT 7 2 ...
Страница 61: ...Mechanical Parts List Type 516 REAR 7 8 ...
Страница 67: ...Mechanical Part List Type 516 LEFTSIDE 7 14 ...
Страница 73: ...Mechanical Parts List Type 516 TOP 7 20 ...
Страница 78: ...POWER VERTICAL AMPLIFIER CHASSIS Mechanical Parts List Type 516 7 25 ...
Страница 107: ...INPUT A INPUT ft T R IG G E R IN P U T C A L O U T A TYPE S I6 OSCILLOSCOPE ...
Страница 111: ... jY P O S C ILLO S C O P E F ...
Страница 114: ...T 1 1 TIM IN G I69 e SWITCH ...
Страница 116: ...C I R C U I T M U M tp S 2 2 5 T H R U 3 8 9 H O R IZ O N T A L A M P L IF IE R ...
Страница 117: ... ...
Страница 120: ... 97 O I V4 93B Z 6D JS VERTICAL OUTPUT STAGE e DELAY LINE C IR C U IT N U M tR S 5 0 T H R U 4 9 9 r p ...
Страница 122: ...P R IM A R Y FAN CO NNECTED FOR 2 3 4 V O PERATIO N I Co IC IR C U ITN U M B E R SI 600T H R U T 5 1 P O W E R SUPPLY ...
Страница 124: ...33 K UNBLANKING PULSE C IR C U IT N U M tP S 6 0 0 TH g U 8 6 9 C R T C IR C U IT TP o oA ...
Страница 125: ...C A L IB R A T O R M U L T IV IB R A T O R i o o v d i v IO O V SE VA RA wr T Y P E B IG O S C I L L O S C O P E ...
Страница 131: ...TYPE 516 CHANGE TO L460 L470 ELECTRICAL PARTS LIST CORRECTION 108 0170 01 0 5 HH 108 0170 01 0 5 HH S16 063 270 ...
Страница 132: ...TYPE 516 ELECTRICAL PARTS LIST AND SCHEMATIC CORRECTION CHANGE TO R478 311 0097 00 200 f t Var f M16 675 870 ...