UPPER-AND LOWER-BEAM VERTICAL
SENSITIVITY.
Selects the sensitivity of the verti
cal amplifier.
DC
BAL.
Used to balance the vertical amplifier
on the high sensitivity ranges of the SENSI
TIVITY control.
POSITION.
Positions the trace vertically.
Input Selector.
Connects inputs from selected
input connector(s) to the vertical amplifier
and also selects either ac or dc coupling of
the input signal.
A.
One of two input connectors to the vertical
amplifier. Inputs applied to this connector
are displayed in the upright position.
B.
One of two input connectors to the vertical
amplifier. Inputs applied to this connector
are displayed in an inverted position.
MISCELLANEOUS
UPPER BEAM FOCUS.
Used to focus the upper
beam.
LOWER BEAM FOCUS.
Used to focus the lower
beam.
INTENSITY.
Controls the intensity of both the
upper and lower beams.
SCALE ILLUM.
Controls the illumination of the
graticule and is the power switch for the
instrument.
Upper Beam Amplifier Connection Indicator.
When lit, this light indicates that the upper
beam amplifier output is connected to the
horizontal deflection plates.
SQUARE-WAVE CALIBRATOR.
Controls the
amplitude of the calibration voltage applied
at the CAL OUT connector.
CAL. OUT.
Output connector for the calibration
voltage selected by the SQUARE-WAVE
CALIBRATOR switch.
HORIZ DEF PLATE SELECTOR.
In the TIME
BASE AMP position, this switch connects the
output of the horizontal amplifier to the
horizontal deflection plates for normal op
eration. When the switch is in the UPPER
BEAM AMP position, the upper beam verti
cal amplifier output is connected to the hori
zontal deflection plates.
GAIN ADJ FOR HORIZ MODE.
Gain adjust
ment control for the upper beam vertical
amplifier when the amplifier is connected to
the horizontal deflection plates. This control
provides compensation for differences be
tween the vertical and horizontal deflection
factors of the crt.
CRT CATHODE.
Connector at the rear of the
instrument for application of beam-intensity
modulation voltages. The intensity modula
tion signals are simultaneously applied to
cathodes of both guns. When not in use,
this connector should be jumpered to the
GND connector with the grounding strap
provided.
GND.
Connector on the rear of the instrument
which is used to provide a ground connec
tion to the CRT CATHODE connector.
3-12
OPERATING INSTRUCTIONS— TYPE 502
®
Содержание 502 series
Страница 2: ......
Страница 6: ......
Страница 7: ...Fig 1 1 Type 502 Oscilloscope with accessories ...
Страница 8: ......
Страница 36: ......
Страница 50: ......
Страница 77: ...0 0 TYPE 502 OSCILLOSCOPE A BLOCK DIAGRAM ...
Страница 79: ...INPUT A M PLIFIE R SECOND D R IV E R O UTPUT A M PLIFIE R C F S AM PLIFIE R X 10 X 100 ...
Страница 82: ...V722 type 502 o s c illo s c o p e HEATER WIRING DIAGRAM A POWER SUPPLY ...
Страница 90: ...M ILLE RRUNUP CIRCU IT 350 V 2 3 M ILUSEC TIME BASE GENERATOR 12 8 58 ...
Страница 94: ...CALIBRATOR MULTIVIBRATOR TYPE 502 OSCILLOSCOPE A ...