Some searches also provide Min and Max navigation buttons that open the Zoom mode and center the waveform in the display
at the minimum or maximum value for that search event in the current acquisition.
Search badges are listed in the order created. Deleting a Search badge does not change the order or names of the remaining
badges. You cannot move Search badges other than to drag them into the Trash Can icon to delete them.
Signal Clipping and Badges
WARNING. Clipping is caused by excessive or dangerous voltage at the probe tip, and/or a vertical scale setting that is not
adequate to display the entire vertical range of the waveform. Excessive voltage at the probe tip can injure the operator and
cause damage to the probe and/or instrument.
This instrument shows a warning triangle symbol and the words Clipping in a Channel badge when a vertical clipping condition
exists. Any measurement badges associated with that channel also indicate a clipping condition by turning the measurement text
red and listing the type of clipping (positive or negative).
To close the clipping message, change the vertical scale to show the entire waveform, disconnect the probe tip from the
excessive voltage source, and check that you are probing the correct signal using the correct probe.
Clipping causes inaccurate amplitude-related measurement results. Clipping also causes inaccurate amplitude values in saved
waveform files. If a math waveform is clipped, it will not affect amplitude measurements on that math waveform.
System badges
System badges (in the Settings bar) display the main Horizontal, Trigger, and Acquisition settings. You cannot delete System
badges.
Getting acquainted with your instrument
22
MSO54, MSO56, MSO58 Installation and Safety Manual
Содержание 5 Series
Страница 2: ......
Страница 6: ......
Страница 66: ...Cleaning the instrument 52 MSO54 MSO56 MSO58 Installation and Safety Manual ...
Страница 70: ...EMC safety and environmental compliance 56 MSO54 MSO56 MSO58 Installation and Safety Manual ...
Страница 76: ...Index 62 MSO54 MSO56 MSO58 Installation and Safety Manual ...
Страница 77: ...5 シリーズ ミックスド シグナル オシロスコープ MSO54 型 MSO56 型 MSO58 型 インストールおよび安全性に関するマニュアル P071351400 071 3514 00 ...
Страница 78: ......
Страница 82: ......
Страница 90: ...安全性に関する重要な情報 viii MSO54 型 MSO56 型 MSO58 型のインストールおよび安全性に関するマニュアル ...
Страница 128: ...本機の設定 36 MSO54 型 MSO56 型 MSO58 型のインストールおよび安全性に関するマニュアル ...
Страница 148: ...機器のクリーニング 56 MSO54 型 MSO56 型 MSO58 型のインストールおよび安全性に関するマニュアル ...
Страница 152: ...EMC 安全 環境に関する適合性 60 MSO54 型 MSO56 型 MSO58 型のインストールおよび安全性に関するマニュアル ...
Страница 157: ...5 系列混合信号示波器 MSO54 MSO56 MSO58 安装和安全手册 P071351400 071 3514 00 ...
Страница 158: ......
Страница 159: ...5 系列混合信号示波器 MSO54 MSO56 MSO58 安装和安全手册 www tek com 071 3514 00 支持 5 系列 MSO 产品固件 V1 0 以及更新版本 ...
Страница 162: ......
Страница 176: ...安装仪器 6 MSO54 MSO56 MSO58 安装和安全手册 ...
Страница 221: ...清洁仪器 清洁 使用干燥柔软的棉布清洁设备外部 请勿使用任何可能损坏触摸屏 外壳 控件 屏幕 标记或标签或者可 能渗入外壳的液体清洁剂或化学品 MSO54 MSO56 MSO58 安装和安全手册 51 ...
Страница 222: ...清洁仪器 52 MSO54 MSO56 MSO58 安装和安全手册 ...
Страница 226: ...电磁兼容 EMC 安全和环境合规性 56 MSO54 MSO56 MSO58 安装和安全手册 ...
Страница 232: ...索引 62 MSO54 MSO56 MSO58 安装和安全手册 ...