• Incorrect Installations
Fig 14: Installation at Conical Tank
Ĕ The conical tank cannot be installed above the feed port.
Ĕ When there is an obstacle in the tank that affects the measurement, installing a reflection plate for
normal measurement is necessary.
Ĕ When there is a material pile, the antenna must be vertically aligned with the material surface.
Ĕ If the material surface is uneven, the angle of the horn must be adjusted by the universal flange to
align the horn with the material surface as much as possible (because the inclined solid surface may
cause echo attenuation or even signal loss).
Fig 13: Installation at Conical Tank in inclined Plane