Kona LoRa IoT Home Sensor TRM
T0005370_TRM
Version 1.2
TEKTELIC Communications Inc.
Confidential
Page 15 of 35
3.4
Sensor Application Configuration
3.4.1
Periodic Tx Configuration
All periodic transducer reporting is synchronized around
ticks
. A
tick
is simply a user
configurable time-base that is used to schedule transducer measurements. For each transducer,
the number of elapsed
ticks
before transmitting can be defined.
Note:
Certain transducer types, such as accelerometer and light, need to be enabled for
periodic reporting. Details are available in each
transducer’s
respective section. Table 3-6 shows
a list of registers used to
configure the Sensor’s periodic transmissions.
Table 3-6: Periodic Transmission Configuration Registers
Address Access Value
# Bytes Description
0x20
R/W
Seconds per
tick
4
Sets the
tick
for periodic events. A value of
0 disables all periodic transmissions.
0x21
R/W
Ticks
per Battery Tx
2
Ticks
between Battery reports. A value of 0
disables periodic battery reports.
0x22
R/W
Ticks
per
Temperature Tx
2
Ticks
between Temp reports. A value of 0
disables periodic Temp reports.
0x23
R/W
Ticks
per RH Tx
2
Ticks
between Humidity reports. A value of
0 disables periodic Humidity reports.
0x24
R/W
Ticks
per Reed Switch
Tx
2
Ticks
between Reed Switch reports. A value
of 0 disables periodic Reed Switch reports.
0x25
R/W
Ticks
per Light Tx
2
Ticks
between Light reports. A value of 0
disables periodic Light reports.
0x26
R/W
Ticks
per
Accelerometer Tx
2
Ticks
between Accelerometer reports. A
value of 0 disables periodic Accelerometer
reports.
0x27
R/W
Ticks
per MCU Temp
Tx
2
Ticks
between MCU Temp reports. A value
of 0 disables periodic MCU Temp reports.
0x28
R/W
Ticks
per PIR Tx /
Ticks per Moisture Tx
2
Ticks
between PIR reports. A value of 0
disables periodic PIR reports.
0x29
R/W
Ticks
per External
Input Tx
2
Ticks
between External Input reports. A
value of 0 disables periodic External Input
reports.