background image

Contents 

TITLE 

 

PAGE 

 

1. GENERAL INSTRUCTIONS 

……………..  1 

1.1 Precaution safety measures

 

……………..  1 

1.1.1 Preliminary 

……………..  1 

1.1.2 During use 

……………..  4 

1.2 Symbols 

……………..  6 

1.3 Instructions 

……………..  7 

 

 

 

2. DESCRIPTION

 

……………..  8 

2.1 Instrument Familiarization 

……………..  8 

2.2 LCD Display 

……………..  10 

2.3 Key pad 

……………..  11 

 

 

 

3. FUNCTION DESCRIPTION

 

……………..  13 

3.1 General Functions 

……………..  13 

3.1.1 DATA HOLD mode 

……………..  13 

3.1.2 

Manual 

ranging 

and 

Autorange mode 

……………..  14 

3.1.3 Battery saver 

……………..  15 

3.1.4 Relative measurement mode   

…………….  15 

 

 

 

Содержание TP40

Страница 1: ...During use 4 1 2 Symbols 6 1 3 Instructions 7 2 DESCRIPTION 8 2 1 Instrument Familiarization 8 2 2 LCD Display 10 2 3 Key pad 11 3 FUNCTION DESCRIPTION 13 3 1 General Functions 13 3 1 1 DATA HOLD mode...

Страница 2: ...measurement 21 3 2 4 Continuity Check 23 3 2 5 Diode Test 26 3 2 6 Frequency measurement 29 3 2 7 Temperature measurement 30 3 2 8 Current measurement 31 3 2 9 NCVhEF 33 3 2 10 PC Link 34 4 TECHNICAL...

Страница 3: ...E PAGE 4 2 5 Continuity Check 39 4 2 6 Capacitance 40 4 2 7 Temperature 40 4 2 8 Current 40 5 MAINTENANCE 41 5 1 General maintenance 42 5 2 Fuse replacement 42 5 3 Battery replacement 43 6 ACCESSORIES...

Страница 4: ...1 Preliminary As the possibilities of high transient overvoltages occurred in today s power systems increase more stringent safety standards are set for the electrical test equipment Transients on el...

Страница 5: ...ected loads Appliance portable tools and other household and similar loads Outlet and long branch circuits Outlets at more than 10 meters 30 feet from CAT III source Outlets at more that 20 meters 60...

Страница 6: ...r conductors Refers to the origin of installation i e where low voltage connection is made to utility power Electricity meters primary overcurrent protection equipment Outside and service entrance ser...

Страница 7: ...ided by the meter may be impaired Use extreme caution when working around bare conductors or bus bars Do not operate the meter around explosive gas vapor or dust Verify a Meter s operation by measurin...

Страница 8: ...nect the test leads from the circuit under test For all dc functions including manual or auto ranging to avoid the risk of shock due to possible improper reading verify the presence of any ac voltages...

Страница 9: ...roduce false readings that can lead to electric shock and personal injury Do not measure voltages above 1000V in Category III or 600V in Category installations When in REL mode the REL symbol is displ...

Страница 10: ...al components Any adjustment maintenance or repair work carried out on the meter while it is live should be carried out only by appropriately qualified personnel after having taken into account the in...

Страница 11: ...ture or high humidity environment 2 DESCRIPTION 2 1 Instrument Familiarization The front panel is shown as in Figure 2 1 explanation being as follows LCD display Used for displaying the measuring resu...

Страница 12: ...ving the red test lead for 6A 10A measurements COM Terminal receiving the black test lead as a common reference A mA uA C Hz mV V V OFF F COM A V Hz CAT III 1000V CAT IV 600V 600mA MAX mA uA FUSED 10A...

Страница 13: ...8 15 13 14 Figure 2 2 LCD screen is shown as in Figure 2 2 with its every symbol s meaning shown as in the Table 1 No Symbol Meaning 1 Indicates negative readings 2 Indicator for AC voltage or curren...

Страница 14: ...AC Voltage detect 7 H The meter is in Data Hold mode 8 REL The meter is in Relative Measurement mode 9 MAX Display maximum data 10 MIN Display minimum data 11 Low battery indication 12 The meter is in...

Страница 15: ...nd exit the Data Hold mode Press it and hold 2 seconds backlight on if press it and hold for 2 seconds again backlight off 2 3 3 RANGE At V V A mA and A 1 Press RANGE to enter the manual ranging mode...

Страница 16: ...ess it again the LCD will display the Minimum Value 4 Press and hold it for two seconds the meter will return to normal measurement state Except Hz Duty and Capacitance 3 FUNCTION DESCRIPTION 3 1 Gene...

Страница 17: ...de autorange and lock the meter in a specific range The Meter defaults to the autorange mode in measurement functions that have more than one range When the Meter is in the autorange mode AUTO is disp...

Страница 18: ...e measurement in all functions except frequency To enter and exit the relative measurement mode 1 With the Meter in the desired function touch the test leads to the circuit on which you want future me...

Страница 19: ...rms between the common terminal and the earth ground The Meter s voltage ranges are 600 0mV 6 000V 60 00V 600 0V and 1000V To measure ac or dc voltage set up and connect the Meter as shown in Figure 3...

Страница 20: ...ac voltage measure the ac voltage first Note the ac voltage range then manually select a dc voltage range equal to or higher than the ac range This improves the accuracy of the dc measurement by ensur...

Страница 21: ...A mA uA C Hz mV V V OFF F COM A V Hz mA uA COM Hz V DC Voltage Figure3 1 Measuring AC and DC Voltage...

Страница 22: ...ed and read the displayed value Some tips for measuring resistance The measured value of a resistor in a circuit is often different from the resistor s rated value This is because the Meter s test cur...

Страница 23: ...ading This is normal for high resistance measuring When the input is not connected i e at open circuit the figure OL will be displayed for the overrange condition A mA uA C Hz mV V V OFF F COM A V Hz...

Страница 24: ...5 1 Set the rotary switch to range 2 Press the SELECT key to select capacitance Test 3 Connect the black and red test leads to the COM and terminals respectively or you can use capacitor test lead 4...

Страница 25: ...A mA uA C Hz mV V V OFF F COM A V Hz mA uA COM Hz COM A V Hz mA uA Figure 3 3 Measuring Capacitance...

Страница 26: ...continuity set up the Meter as shown in Figure 3 4 1 Set the rotary switch to range 2 Connect the black and red test leads to the COM and terminals respectively 3 Connect the test leads to the resist...

Страница 27: ...A mA uA C Hz mV V V OFF F COM A V Hz mA uA...

Страница 28: ...A mA uA C Hz mV V V OFF F COM A V Hz mA uA Figure 3 4 Checking the Continuity...

Страница 29: ...est 3 Connect the black and red test leads to the COM and V terminals respectively 4 For forward bias readings on any semiconductor component place the red test lead on the component s anode and place...

Страница 30: ...A mA uA C Hz mV V V OFF F COM A V Hz mA uA...

Страница 31: ...A mA uA C Hz mV V V OFF F COM A V Hz mA uA Figure 3 5 Measuring Capacitance...

Страница 32: ...play 3 To make a duty cycle measurement press the Hz key again 4 Read the percent of duty cycle on the display 5 Set the rotary switch to the Hz range 6 Insert the black and red test leads into the CO...

Страница 33: ...60v dc or 24v rms Ac To avoid damage or burns Do not make temperature measurement in microwave ovens To measure temperature 1 Set the rotary switch to range and the LCD will show the current environm...

Страница 34: ...are 600 0 A 6000 A 60 00mA 600 0mA 6 000A and 10 00A To measure current set up the Meter as shown in Figure 3 6 1 Turn off power to the circuit Discharge all high voltage capacitors 2 Set the rotary...

Страница 35: ...measurement units at the right side of the display A mA or A When only the figure OL displayed it indicates overrange situation and the higher range has to be selected 7 Turn off power to the circuit...

Страница 36: ...uring Current 3 2 9 NCV Non Contact Voltage detect Set rotary switch to the ACV range Press the SELECT key to go NCV detect mode Put the EF DETECT AREA close to the AC power cable or the power socket...

Страница 37: ...ss REL more than 2 seconds and the meter enter PC Link mode the symbol PC LINK will appear on LCD and the serial data output function is active Auto power off function is disable when PCLINK function...

Страница 38: ...d ports If no errors occur the USB to Serial COM Port COM x will appear COM x is just the proper port here x is a specific number 5 Now the PC LINK SOFT view the synchronic data or graph in the softwa...

Страница 39: ...ic and manual Over Range indication LCD will display OL Low battery indication The is displayed when the battery is under the proper operation range Polarity indication displayed automatically Power s...

Страница 40: ...CV Range Resolution Accuracy 600mV 0 1mV 1 0 of rdg 5 digits 6V 1mV 60V 10mV 600V 100mV 750V 1V 1 5 of rdg 5 digits Above accuracies can be guaranteed within 5 100 of the full range The RMS meter has...

Страница 41: ...10M 4 2 2 Frequency Logic frequency 1Hz 1MHz Range Resolution Accuracy 99 99Hz 0 01 Hz 0 1 of rdg 3digits 999 9Hz 0 1 Hz 9 999kHz 0 001kHz 99 99kHz 0 01kHz 999 9kHz 0 1kHz Linear frequency 6HZ 10KHZ R...

Страница 42: ...0 0k 100 6 000M 1k 60 00M 10k 1 5 of rdg 5 digits 4 2 4 Diode Test Range Resolution Test Condition 1 V 0 001V Forward DC current approximately 1mA Reversed DC voltage approximately 1 5V 4 2 5 Continui...

Страница 43: ...1 F 5 0 of rdg 20 digits 4 2 7 Temperature Range Resolution Accuracy 200 0 1 5 0 of rdg 4 0 400 2 0 of rdg 3 400 1200 2 0 of rdg 2 Note The specifications of temperature don t include thermocouple err...

Страница 44: ...the accuracy of measurement 1 Frequency Range for ACA 40Hz 400Hz 2 Overload protection F 10A 1000V fuse for 10A Overload protection F 0 63A 1000V fuse for A and mA ranges 3 Maximum input current 600m...

Страница 45: ...moisture in the terminals can affect readings To clean the terminals Turn the meter off and remove all test leads Shake out any dirt that may be in the terminals Soak a new swab with a cleaning and o...

Страница 46: ...10 3 38 7 Rejoin the rear cover and tighten the screws 5 3 Battery replacement To avoid false readings which could lead to possible electric shock or personal injury replace the battery as soon as the...

Страница 47: ...ce with one new 9V battery 6F22 7 Rejoin the battery cover and tighten the screws 6 ACCESSORIES Delivered with the multimeter User s manual One piece Test leads One piece K type Thermocouple One piece...