1
User Guide
TP3016M Series
Switching Mode DC Power Supply
Страница 1: ...1 User Guide TP3016M Series Switching Mode DC Power Supply...
Страница 2: ...n 1 2 Pre Checking 1 3 Quick Start 1 4 Output Checking II Specifications 2 1 Major Specification 2 2 Supplementary Characteristic III Operation 3 1 Keypad 3 2 Front Panel 3 3 Voltage Setting 3 4 Curre...
Страница 3: ...3 3 7 Recall Saving Operation 3 8 USB Power Charging IV Calibration 4 1Voltage Calibration 4 2 Current Calibration...
Страница 4: ...he markings and labels of this unit to be connected Do not install the substituted spare parts or operate the modification without permission please send the unit back for A S to our authorized dealer...
Страница 5: ...result in damage to equipment and improper functioning of power supply Grounding High Voltage Attention on the Warning or Caution Specification Compliance TP3016M Switch mode DC Power Supply is compli...
Страница 6: ...ltage and current through the keypad of front panel and save the setting groups for further performance TP3016M also has the 4 digit voltage and current meter as well as the fantastic handheld size Th...
Страница 7: ...k points on TP3016M for making sure the proper operation as well as the functions of TP3016M 1 1 Front Panel Description 1 Current Setting Indicator 2 Voltage Setting Indicator 3 Measured Value Displa...
Страница 8: ...8 1 2 3 4 5 6...
Страница 9: ...ion User Guide 1PC Connect with power and switch on TP3016M the unit start the self system checking the LCD displays 0 5s date of manufacturing production lot model number version number in turn 1 3 Q...
Страница 10: ...ecrease the contrast of LCD Press RIGHT arrow key to increase the contrast of LCD V A Key Press the V A key to activate voltage measurement and read the voltage value from display Push the V A key aga...
Страница 11: ...button by pressing the direction arrow keys to adjust the voltage value setting Push the V A button to switch the current value setting mode by pressing the direction arrow keys to measured current v...
Страница 12: ...power supply under constant current mode 1 Switch on the product the power is off and the indicators of CC CV are light off 2 Adjust voltage value as 30V 3 Connect the resistance 3 50W between output...
Страница 13: ...function check This is for checking USB charging function 1 Switch on the product the power is off and the indicators of CC CV are light off 2 Push and light the USB button Adjust the voltage as 5 1V...
Страница 14: ...A Measurement Accuracy Voltage 10mV Current 1mA Measured Value Accuracy 25 of output offset Voltage 0 05 5mV Current 0 05 5mA Measurement Speed Voltage 100ms ones Current 100ms ones Setting Value Accu...
Страница 15: ...ature 0 to 40 Storage Temperature 20 to 70 III Operation Check the rating label of the power supply and ensure that it complies with the AC mains voltage that is to be used Connect the power supply to...
Страница 16: ...g range is from 0 50V to 30V follow the setting steps as below 1 Switch on the power supply 2 Push the OUT button to stop the output setting and light off OUT button 3 Push and light the SET ENTER but...
Страница 17: ...1 66A follow the setting steps as below 1 Switch on the power supply 2 Push the OUT button to stop the output setting and light off OUT button 3 Push and light the SET ENTER button the max value posi...
Страница 18: ...button again to exit output mode 3 6 Data Saving Operation 1 Under the voltage setting or current setting mode push the STORE button to save the values of voltage or currents into memory of power sup...
Страница 19: ...on the power supply 2 Push RECALL button to enter data recall mode the min value position is flickering and displayed RECALL icon in LCD 3 Move UP or DOWN arrow keys to recall the stored group serial...
Страница 20: ...can be as 0A Connect the mobile phone via USB cable for power charging The USB ports are suitable for both android mobile phone and l Iphone with automatic check function the product can set the prop...
Страница 21: ...er current meter resistance 10 100W into the output terminals calibration follow the steps start from point of zero voltage voltage coefficient current zero current coefficient Hold the SET button to...
Страница 22: ...LEFT or RIGHT arrow keys to move the cursors to left or right and push the UP or DOWN arrow keys to adjust the values same as readings of external reference voltage meter then click ENTER button to f...
Страница 23: ...keys to move the cursors to left or right and push the UP or DOWN arrow keys to adjust the values same as readings of external reference voltage meter then click ENTER button to finish the current gai...