GATEWAY ANALOG OUTPUTS
04
Link
Analog Output Index 1
(Gateway) to
Pulse Counter 1
(Transmitter) and configure MB Add Link according to
the previous step. Set minimum and maximum values and click on
Write
WIRELESS GATEWAY
Green led permanently on
during a closed current loop
Red led permanently on
during an open current loop
NOTE:
Output index 1 is linked to modbus address [9], according to mapping table of step 03.
Modbus address double word (float 32) value is converted into 4..20 mA scale according to minimum and
maximum defined values.
4000 (4mA)
20000 (20mA)