teko RTD Astra-Y Скачать руководство пользователя страница 1

                                                                                                                                          ver.

 UOP-Yv2_6_en 

 

«RTD Astra-Y» 

 

Receiving terminal device (receiver)  

 

Operating manual 

 

 

 

 

 

This operation manual is intended to study the principle of op-
eration,  correct  use  and  maintenance  of  the  radio  receiver 
"RTD Astra-Y" (firmware Y-UOP-v4_0 and higher) (Figure 1). 
The  manufacturer  reserves  the  right  to  make  changes  in  the 
design,  software,  circuitry  solutions  and  product  configuration 
that do not degrade its technical characteristics, do not violate 
mandatory regulatory requirements, without prior notice to the 
consumer.

 

 
List of abbreviations

 
ARM-Y 

– software for configuration and monitoring of the sys-

tem (for windows 7 or higher); 

OC 

– “open collector” output; 

PC

 

– personal computer; 

CP 

– control panel Astra-712; 

Astra-Y MP

 

– Astra-Y monitoring panel; 

Astra-Y system

 

– wireless monitoring system «Astra-Y»; 

TTD

 

– radio transceiver “TTD Astra-Y”; 

RTD

 

– radio receiver «RTD Astra-Y»; 

AL

 

– alarm loop (hardwired zone). 

 

   

 

Purpose 

 

1.1 

RTD is designed to receive over the radio channel notifi-

cations from registered TTDs, decode and send notifications to 
three  built-in  LED  indicators,  two  signal  relays  and  one  OC 
output, as well as via the LIN interface in standalone operating 
mode or via the RS-485 interface in extended operating mode. 

1.2 

The main purpose is the organization of centralized moni-

toring  via  radio channel  (433 MHz)  of  cottage  settlements,  in-
dustrial facilities, etc. 

1.3 

The radio channel communication between the  RTD and 

the TTD is two-way. 

1.4 

RTD  supports  up  to  48  of  TTD  in 

standalone operating mode and up to 250 of 
TTD in extended operating mode. 

1.5 

RTD  supports  working  in 

standalone 

mode

 without connected Astra-Y MP.  

1.6 

Remote  indication  panel  unit  Astra-861 

can  be  connected  to  the  RTD  in  standalone 
mode via the LIN interface. 

1.7 

RTD  supports  working  in  extended 

mode, connecting via RS-485 interface to the 
Astra-Y MP or to a PC with installed software 
ARM-Y  through  connector  F7.  To  connect  to 
a PC, the Astra-984 interface unit is used. 

1.8 

RTD  supports  two-level  retransmission 

of  the  signal  and  tracks  the  routes  of  signals  through  TTD  re-
peaters.  Current  routes  can  be  viewed  using  the  ARM-Y  soft-
ware in the configuration mode. 

 

Specifications 

 

Technical parameters of the radio channel 

Operation frequency range, MHz ....................... 433,92 

± 0,2 % 

Number of the frequency channels ......................................... 16 
Power of the RTD transceiver*, mW, .......................... 10/30/100  
Wireless coverage range*

*

 between RTD and TTD, m, up to: 

- with standard whip antenna (0,17 m length) 
power 10/100 mW ..................................................... 2500/3400 
- with external antenna (3 dB gain) 
power 10/100 mW ..................................................... 4500/8700 
The sensitivity of the RTD receiving path,  
dBm, not more ....................................................................  -102  
RF supervision time***, min ..................................... from 3 to 40 
Radio exchange rate, bit/sec ............................................ 19200 

 

 

General technical parameters  

Power supply voltage, V ................................  from 10,5 to 15,0 
Current consumption, mA, not more: 
- receiving mode .................................................................. 115 
- 10 mW power .................................................................... 200 
- 30 mW power .................................................................... 200 
- 100 mW power .................................................................. 230 
Boot time, sec, not more .......................................................... 5 

 

Outputs 

Relay 1, 2 (terminals 

Relay1, Relay2

)

:

 

- max load voltage, V ........................................................ 100 
- max load current, mA ...................................................... 100 

«Open collector» output (terminal

 OC

)

:

 

- max load current, 

мА ...................................................... 100 

- max load voltage DC, V .................................................... 45 

RS-485 interface:

 

Interface line length, m, not more .................................... 1000 
Exchange rate, bit/sec..................................................... 9600 

LIN interface:

 

Interface line length, m, not more ...................................... 200 
Active resistance of the wires, Ohm, not more .................. 100 
Capacity between the wires, uF, not more ..................... 0,033

 

LIN interface exchange rate, bit/sec ................................ 4800 

Overall dimensions (without antenna), mm .......... 

121 × 79 × 31 

Weight (without antenna), kg, not more ................................ 0,1 

Operation conditions 

Temperature range, 

о

С ..................................... .from -10 to +50 

Relative air humidity,

........................................ .to 95 at +35

without moisture condensation 

Delivery set 

 

RTD: 
Astra-Y RTD ..................................................................... 1 pcs. 
Whip antenna .................................................................... 1 pcs. 
Screw 2,9

×25 .................................................................... 4 pcs. 

Dowel 5

×25 ....................................................................... 4 pcs. 

Operating manual ........................................................... 1 copy. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

__________________________________________________ 

*   factory default value is 10 mW. 
**

 

in line of sight. The radius of action largely depends on the design 

features of the room, the installation site, and the interference envi-
ronment. 
*** factory default value is 10 min. 

 

Figure 1 

Отзывы: