![teko Astra-Z-2345 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/teko/astra-z-2345/astra-z-2345_operation-manual_1077185002.webp)
Revision 2345-v1_5_en
2
5
Notifications
Table 1: Notifications issued on the
Light
Channel
Notification
Red
Green
Blue
Standby
mode start
One-time
sequential indication of each color
for
0.1 seconds
Exit delay
time
Blinks
once
per
2 seconds
within delay
time
OFF
OFF
Alarm/Fire
Blinks
once
per second
within the
sound alerting
period, then
–
once every 10
seconds
OFF
OFF
Arming
Lights up for
10 seconds
OFF
OFF
Disarming
OFF
Lights up for
10 seconds
OFF
No network
OFF
OFF
Double
blink
for 0.1
seconds
every 25
seconds
Network
search
OFF
OFF
Blinks with
frequency of
5Hz
during
1
to 60
seconds
Table 2: Notifications issued on the
Sound
Channel
Notification
Acoustic Signal
Alarm
Continuously ON for
10 minutes
Fire
Intermittently ON
every 1 second with off-
duty ratio 2
during
10 minutes
Table 3: Notifications issued to
Service
LEDs and control panel
Notification
White
LED
Red
LED
Control
Panel
Standby
mode start
OFF
Lights up for
1
to 20 seconds
-
Normal
OFF
OFF
+
Tamper
OFF
Lights up
once
for
1 second
+
Power ON
OFF
+
Failure of
primary
battery
OFF
OFF
+
Failure of
secondary
battery
OFF
OFF
+
Power
failure
OFF
Triple blink
for
0.1 seconds
with
pause of 0.5
seconds every
25
seconds
+
Network
search
Blinks with
frequency of
5Hz
during
1 to 60 seconds
OFF
-
No network
Double blink
for
0.1 seconds
with
pause of 0.5
seconds every
25
seconds
OFF
-
+: notification issued;
–: notification not issued
Notes
1
If
«Primary battery failure»
notification appears,
change
both batteries within
two months
.
2
The
«Power failure»
notification is processed by the
red
LED if
both batteries are discharged or if one of the batteries is missing
and the second battery is discharged.
3
Upon simultaneous power supply voltage decrease of the
main and backup batteries
below 2,4 V
, the siren ceases
operation while retaining LED indication.
4
The siren indicates
«Armed/Disarmed» status of partitions to
which it is assigned when pressing
«
» button on Astra-Z-
3245 key fob. The key fob must be registered in the network
and have user rights for arming/disarming.
6 Pre-Starting Procedure
6.1
After transportation in conditions differing from those of
operation, siren must be kept unpacked for 4 hours in the
expected operating conditions.
6.2 Running Siren. Replacing Batteries
WARNING!
Lithium-thionyl-chloride batteries have an effect of
«passivation» to provide the possibility of long-term storage. To
provide battery normal operation after long-term storage, hold
an
«activation» procedure.
«Activation» occurs when inserting battery into LSA.
Step-1
Remove the housing cover by
removing 3 screws that fasten the
cover to the base.
Step-2
Insert primary and secondary batteries with the correct
polarity (to replace the battery, remove the old one and after
at least 30 seconds insert the new one).
The red LED lights up for
1 to 20 seconds
.
If after 60 seconds the
red
LED flashes
triply
every 25
seconds, re-activate the battery by removing it, and after at
least 30 seconds reinserting it.
WARNING!
It is
strictly forbidden
to "activate"
SAFT LSH 14
battery by
short circuit between the poles of battery or exceed the load
current 2 A, as battery is built in safety fuse which irreversibly
destroyed in case of overload.
6.3 Registering the Siren in the Wireless Network
Siren registration procedure is required for identification in the
wireless network in which it is supposed to operate.
Step-1
According to Astra-Zitadel System Control Panel`s
Operating Manual *
perform the following procedure:
1)
Install
Software **
(MSS Astra-Z, Pconf-Z or MSS Astra
Pro) intended for configuring Control Panel;
2)
Create wireless network.
Step-2
Perform steps described in
p. 6.2
.
Step-3
Make sure alerter issues "No network" notification.
Otherwise, perform deletion of the alerter from wireless
network in accordance with
p.6.4
.
Step-4
Switch the control panel to
Wireless device registration
mode by the method described in the appropriate Astra-Zitadel
System Control Panel`s
Operating manual*
.
Step-5
Initiate siren registration procedure by one of
2 methods
:
a) using the
LT
(step-6);
b) using the
Reg
plug and the
detach switch