teko Astra-Z-2345 Скачать руководство пользователя страница 2

                                                                                                                                               

Revision 2345-v1_5_en

 

Notifications 

 

Table 1: Notifications issued on the 

Light

 Channel 

 

Notification

 

Red 

Green 

Blue 

Standby 
mode start 

One-time

 sequential indication of each color 

for 

0.1 seconds

 

Exit delay 
time 

Blinks 

once

 

per  
2 seconds

 

within delay 
time 

OFF 

OFF 

Alarm/Fire 

Blinks 

once 

per second

 

within the 
sound alerting 
period, then 

–  

once every 10 
seconds

 

OFF 

OFF 

Arming 

Lights up for 

10 seconds

 

OFF 

OFF 

Disarming 

OFF 

Lights up for 

10 seconds

 

OFF 

No network 

OFF 

OFF 

Double 
blink

 for 0.1 

seconds   
every 25 
seconds 

Network 
search 

      OFF 

OFF 

Blinks with 
frequency of 

5Hz

 during 

to 60 
seconds

 

 

Table 2: Notifications issued on the 

Sound

 Channel 

 

Notification

 

Acoustic Signal

 

Alarm 

Continuously ON for 

10 minutes

 

Fire 

Intermittently ON 

every 1 second with off-

duty ratio 2

 during 

10 minutes

 

 

Table 3: Notifications issued to 

Service 

LEDs and control panel 

 

Notification

 

White 

 

LED

 

Red 

 

LED

 

Control 

Panel

 

Standby 
mode start 

OFF 

Lights up for 

to 20 seconds

 

Normal 

OFF 

OFF 

Tamper 

OFF 

Lights up 

once 

for 

1 second

 

Power ON 

OFF 

Failure of 
primary 
battery 

OFF 

OFF 

Failure of 
secondary 
battery 

OFF 

OFF 

Power 
failure 

OFF 

Triple blink

 for 

0.1 seconds

 with 

pause of 0.5 
seconds every 

25 

seconds

 

Network 
search 

Blinks with 
frequency of 

5Hz

 

during  

1 to 60 seconds

 

OFF 

No network 

Double blink

 for 

0.1 seconds

 with 

pause of 0.5 
seconds every 

25 

seconds

 

OFF 

+: notification issued; 

–: notification not issued 

 
Notes

 

1

  If 

«Primary  battery  failure»

  notification  appears, 

change 

both batteries within 

two months

 

2

 The 

«Power failure»

 notification is processed by the 

red

 LED if 

both batteries are discharged or if one of the batteries is missing 
and the second battery is discharged. 

Upon  simultaneous  power  supply  voltage  decrease  of  the 

main  and  backup  batteries 

below  2,4  V

,  the  siren  ceases 

operation while retaining LED indication.

 

4

 The siren indicates 

«Armed/Disarmed» status of partitions to 

which  it  is  assigned  when  pressing 

«

»  button  on  Astra-Z-

3245  key  fob.  The  key  fob  must  be  registered  in  the  network 
and have user rights for arming/disarming. 

 

6  Pre-Starting Procedure 

 

6.1 

  After  transportation  in  conditions  differing  from  those  of 

operation,  siren  must  be  kept  unpacked  for  4  hours  in  the 
expected operating conditions. 

 

6.2  Running Siren. Replacing Batteries

 

 

WARNING! 

Lithium-thionyl-chloride  batteries  have  an  effect  of 

«passivation» to provide the possibility of long-term storage.  To 
provide  battery  normal  operation  after  long-term  storage,  hold 
an 

«activation» procedure. 

«Activation» occurs when inserting battery into LSA.

 

 

Step-1

 

Remove  the  housing  cover  by 
removing  3  screws  that  fasten  the 
cover to the base. 

 
 
 

Step-2 

Insert  primary  and  secondary  batteries  with  the  correct 
polarity (to replace the battery, remove the old one and after 
at least 30 seconds insert the new one).

 

The red LED lights up for 

1 to 20 seconds

If  after  60  seconds  the 

red

  LED  flashes 

triply 

every  25 

seconds,  re-activate  the  battery  by  removing  it,  and  after  at 
least 30 seconds reinserting it. 

 

WARNING!

 

It is 

strictly forbidden

 to "activate" 

SAFT LSH 14

 battery by 

short circuit between the poles of battery or exceed the load 
current 2 A, as battery is built in safety fuse which irreversibly 
destroyed in case of overload. 

 

6.3  Registering the Siren in the Wireless Network 

 

Siren registration procedure is required for identification in the 
wireless network in which it is supposed to operate. 

 

Step-1 

According  to  Astra-Zitadel  System  Control  Panel`s 

Operating Manual *

 perform the following procedure: 

1)

 Install 

Software ** 

(MSS Astra-Z, Pconf-Z or MSS Astra 

Pro) intended for configuring Control Panel; 

2) 

Create wireless network. 

 

Step-2 

Perform steps described in 

p. 6.2

 

Step-3 

Make sure alerter issues "No network" notification. 
Otherwise,  perform  deletion  of  the  alerter  from  wireless 
network in accordance with 

p.6.4

 

Step-4

 

Switch  the  control  panel  to 

Wireless  device  registration

 

mode by the method described in the appropriate Astra-Zitadel 
System Control Panel`s 

Operating manual*

 

Step-5 

Initiate siren registration procedure by one of 

2 methods

a) using the 

LT 

(step-6); 

b) using the 

Reg

 plug and the 

detach switch 

(step-7). 

 
 