5.3.2  Installing the module in the Control Panel 812 Pro : 

1) 

Turn off the power of the Control Panel 812 Pro. 

2) 

Remove  the  base  of 

the  Control  Panel  812 
Pro  by  unscrewing  the  4 
screws  from  the  side  of 
the base. 

3) 

Install  the  terminal 

block  board  from  the  de-
livery set and the module 
itself  on  the  PCB  812 
Pro  from  the  side  of  the 
base. 

 

4) 

Install the base 

5) 

Open 

the 

keypad 

cover  of  the  Control 
Panel 812 Pro 

6) 

Remove  the  terminal 

compartment  cover  by 
unscrewing  the 2 screws 
securing it.  

 

7) 

Pass  the  network  interface  wires  through  the  wire  entry 

hole, ensure hidden wiring to the terminals of the Control Panel 
812 Pro is carried out in accordance with section 7 (table 2). 

8) 

Replace the cover of the terminal compartment, tighten the 

two screws. Close the keypad cover if necessary. 

 

6  SETUP 

Module  configuration  is  carried  out  using  a  computer  and  the 
PKM program Astra-Pro according to the method described in 
the User's Manual of the software. 
When  using  the  module  as  part  of  the  Astra-812  Pro  control 
panel, it is possible to add and configure it through the built-in 
keypad and display of the Astra-812 Pro control panel accord-
ing to the instructions for the Astra-812 Pro control panel. 

 

7  CONNECTION TO THE NETWORK 

 

The control panel PCB contains screw terminals for connecting to 
the  Ethernet  network  (connection  to  the  control  panel  812  Pro  is 
made through the terminals of the installed terminal board). 

Terminals functions 

is presented in

 

Tables 1, 2: 

Table 1 

– Control Panel 8945 Pro 

CP terminals 

Terminals function 

 
 

 

Terminals  are  used  when  installing  the  
module in slot A: 

A1

 - to connect Tx-; 

A2

 - to connect Tx+; 

A3

 - to connect Rx-; 

A4

 - to connect Rx+. 

Terminals  are  used  when  installing  the  
module in slot B: 

B1

 - to connect Tx-; 

B2

 - to connect Tx+; 

B3

 - to connect Rx-; 

B4

 - to connect Rx+.

 

 

Table 2 - Control Panel 812 Pro

 

Control Panel 

terminals 

Terminals function 

 

 

 
A1

 - to connect Tx-; 

A2

 - to connect Tx+; 

A3

 - to connect Rx-; 

A4

 - to connect Rx+. 

 
Network  connection  must  be  provided  with  a 

TIA/EIA-568-B

 

crossover type network cable. 

 

 

The connection diagram is shown in the figure

:  

If module is installed into slot A of the Control Panel 8945 Pro, 
or into the Control Panel Astra-812 Pro slot: 

 

when installed into slot 

B

 of the 8945 Pro Control Panel 

 

 

WARRANTY 

 

9.1  Warranty  period  of  operation  -  2  years  from  the  date  of 
commissioning,  but  not  more  than  2  years  6  months  from  the 
date of manufacture. 
9.2  Average module life is 10 years. 
9.3 

The  warranty  does  not  take  effect  in  the  following 

cases

:  

– 

non-observance of this user guide; 

– 

mechanical damage to the module;  

– 

module repair by a person other than the manufacturer. 

9.4  The  warranty  only  applies  to  the  module.  All  third  party 
equipment used with the module is covered by their own war-
ranties. 

 

The  manufacturer  is  not  liable  for  any  damage  to  health, 
property, or other incidental or special loss, direct or indi-
rect  damages  based  on  the  user's  claim  that  the  module 
did not fulfill its functions, or as a result of misuse, failure 
or temporary inoperability of the module. 

 

 