6 Information Capacity
Table 1
– Notifications to Indicator and Relay
Notification
type
Indicator
Relay
Starting
detector to
standby
mode
Blinks
once per 1 s
after
power up.
Duration up to
60 s
Relay is open
for up to
60 s
Norm
Not lit
Relay is closed
Alarm
Lights up
once for 4 s
at
detection
of
man
movement in detection
zone (when indication is
enabled)
Relay opens for
4 s
Alarm in
“Alarm mem-
ory” mode
Fig. 4
Relay is in the
standby mode
Alarm
during TEST
pass
Lights up
once for 2 s
at
detection
of
man
movement in detection
zone
Relay opens for
2 s
Fig. 4
7 Operating Modes
Table 2
– Operating modes and settings
Operating mode
Plug
Jumper position
High detectability
Normal detectability
Sens
+
–
Indication ON
Indication OFF
Ind
+
–
“Alarm memory” ON
“Alarm memory” OFF
Mem
+
–
TEST-pass
(switches ON for 8 min)
Ind
For a short mo-
ment (for 2-3s)
change
jumper
position on the
plug
Ind
during
starting of detec-
tor
operating
mode
"
+
" - jumper is installed on both plug pins
"
–" - jumper is removed (or installed on one
plug pin)
The “Alarm memory” mode
allows registering the fact
and number of zone violations in prortected area, and is
reflected in corresponding notification.
The mode is activated in 1 minute after installation of jumper
on
Mem
plug or in 1 min. after starting of detector stand-by
mode with jumper installed previously on
Mem
plug.
“Alarm”
notification is indicated in 1 min. after violation of protected
area. To switch the mode OFF and reset indication, remove
jumper from
Mem
plug or switch power OFF.
TEST-pass
allows revealing precise location of sensitive
zones formed by the lens. On expiry of 8 min the detector
automatically starts its stand-by mode.
8 Installation and Pre-starting Procedure
8.1
Works on installation, mounting, maintenance and
operation of detector should be performed by only qualified
persons.
8.2
After transportation in conditions differing from those of
operation keep detector unpacked under supposed operation
conditions for at least 4 hours.
Then unpack the detector.
8.3 Selection of Installation Place
8.3.1
Recommended height of installation
8.3.2
In capital buildings it is recommended to install detector
on a bearing wall.
8.3.3
In light metalwork buildings one should avoid to install
detector directly on the wall, it is recommended to install
detector on bearing carriers.
8.3.4
Wires of signaling zones and power supply circuits should
be located far from power cables.
8.3.5
It is recommended to close all doors, air-vents, switch off
fans, air-conditioners and other sources of intense air flows in
the room during protection period.
8.3.6
Non-recommended mounting locations
8.4 Installation Procedure
Step-1
Push out cover
lock from base slot.
Remove cover
Step-2
Unbend hooks
of the base. Remove PCB
Hooks
Step-3
Press out the blank of a se-
lected wire insertion hole
Indication is
ON
Indication is
OFF
2 s
2 s
2 s
2 s
2 s
2 s
0.5 s 0.5 s 0.5 s
1 s
2s
s
2s
s
2s
s
4 s
1 s
1 s
1 s
Number of alarm
events (up to 3)
Reiterated
indication
c
b
Start of indication
m