background image

 

 

 

Astra-9 (Volumetric Lens)  

 

Optic-Electronic PIR Motion Detector 

 

Operating Manual 

 

 

 

 

 

 

 

Rev. 9-v3_7_en

 

 

   

 The present operation manual is intended for studying operation 
principle, running conditions and maintenance of PIR motion de-
tector Astra-9 (

hereinafter referred to as “the detector”) (Fig.1). 

 

1  Function 

 

Detector 

is 

intended 

to 

detect 

unauthorized 

access 

into 

closed 

protected area, and to generate an alarm 
notification    by  opening  of  alarm  relay 
contacts. 
Power  supply  of  detector  is  performed 
from  any  direct  current  source  with 
nominal  voltage  12V  and  pulsation 
amplitude not exceeding 0,1V. 

 

2  Operating Principle 

 

 Operation  principle  is  based 
on  registration  of  changes  in 
thermal 

emission 

flux 

occurring  on  crossing  by  a 
man 

of 

detection 

zone 

consisting of sensitive zones. 
Each sensitive zone consists 
of  two  elementary  sensitive 
zones (figure 2). 
The  sensitive  zones  are 
formed by a Fresnel lens and 
a bi-areal pyroelectric sensor.    
An  electric  signal  from  the 
pyroelectric sensor is sent to 
a  microcontroller  which 

–  in 

accordance  with  a  preset 
operation  algorithm 

–  gene-

rates  an 

“Alarm”  notification 

by  opening  optoelectronic 
relay circuit. 

 

The  detection  zone  size  can 
be  changed  by  changing  po-
sition  of  the  detector  printed 
circuit  board.  If  the  intrusion 
detection  range  is  reduced  to  7  m,  density  of  the  sensitive 
areas will increase.

 

 

3  Specifications 

 

Optical Channel Parameters 

Intrusion detection range, m, min: 
- in the lower PCB position  ............................................................ 10 
- in the upper PCB position .............................................................. 7 
Detection zone size at the detection angle  
of 90

о

 in horizontal plane, m: 

- in the lower PCB position .................................................. 10

×10 

- in the upper PCB position ........................................................... 

7×7 

Movement speed detection range, m/s........... from 0.3 up to 3.0 
Resistance to ambient light, lx, min ...................................  6500  
Recommended installation height, m.............  from 2.4 up to 2.5 

General Technical Parameters

 

Power supply voltage, V .................................... from 8 up to 15 
Current consumption in standby mode and  
in “Alarm” mode, mA, max ..................................................... 15 
Relay contacts permissible current, m

А, max ..................... 0.08 

Relay contacts permissible voltage, V, max ......................... 100 
Resistance of circuit, connected to signaling zone  
in standby mode, Ohm, max  ................................................... 8 
Overall dimensions, mm, max .................................... 76

×58×46 

Weight, kg, max ................................................................ 0.085

 

 
Operating Conditions 

Temperature range, 

°

С ................................. from -30 up to +50   

Relative air humidity, % ....................................... up to 95 at + 35 

°

С 

 

no moisture condensation 

 

4  Delivery Set 

 

PIR motion detector Astra-9 ............................................... 1 pcs. 
Screw 2.9x25 (2-3

х30) ....................................................... 2 pcs. 

Dowel 5

х25 ........................................................................ 2 pcs. 

Sealing material ................................................................. 1 pcs. 
Bracket-01  ........................................................................ 1 pcs. 
User Instruction ................................................................ 1 copy. 

 

5  Structure 

 

 

 

Fig. 3 

 

Structurally,  the  detector  is  designed  as  a  unit  consisting  of  a 
base  and  a  removable  cover.  Printed  circuit-board  with 
radioelements  and  screw  terminal  block  for  external 
connections are mounted inside the unit (Fig. 3).  
Mounted  on  the  detector  base  is  an  eccentric;  by  rotating  the 
eccentric  one  can  change  the  position  of  the  printed  circuit 
board.  
Mounted on the circuit board is an indicator for detector operabil-
ity supervision. 
Mounted  inside  the  detector  cover  is  a  fixing  piece  pressing 
down the lens and fixing its position.  
The pyroelectric sensor is equipped with a reflector cap which 
forms short-range detection zone. 

 

WARNING! It is prohibited to operate the detector without 
the cap. 

 

Fig. 2 

Fig 1 

Side view 

Tope view 

1m          3,5m        7m           10m 

5m           

 
 
 
 
 

 

 
 
 
 
 

 

5m            

2,5m          

10m          

Cover removed 

Bracket  
mounting slot 

Wire inser-
tion hole 

Screw  
terminals 

Jumpers 

Eccentric 

Mem plug 

Reflector 

Sens plug 

Pyroelectric  
sensor 

Ind plug 

Cap 

Indicator 

 
PCB 

Base 

Содержание Astra-9

Страница 1: ...0 in the upper PCB position 7 7 Movement speed detection range m s from 0 3 up to 3 0 Resistance to ambient light lx min 6500 Recommended installation height m from 2 4 up to 2 5 General Technical Parameters Power supply voltage V from 8 up to 15 Current consumption in standby mode and in Alarm mode mA max 15 Relay contacts permissible current mА max 0 08 Relay contacts permissible voltage V max 1...

Страница 2: ...otected area To switch the mode OFF and reset indication remove jumper from Mem plug or switch power OFF TEST pass allows revealing precise location of sensitive zones formed by the lens On expiry of 8 min the detector automatically starts its stand by mode 8 Installation and Pre starting Procedure 8 1 Works on installation mounting maintenance and operation of detector should be performed by only...

Страница 3: ... wires to detector terminals Step 10 Using sealing material of distribution kit seal hermetically wire insertion hole and other holes to protect detector from air and insects ingress Step 11 Remove jumper from the Mem plug Install jumpers on Sens and Ind plugs Step 12 Turn the detector ON the indicator blinks once per 1 s for no longer than 60 s it means the detector is be ing switched to the oper...

Страница 4: ...n tech nology equipment 11 Recycling The detector does not pose any life or health risk to individuals or to the environment Once its service life is complete the detector may be utilized with no special environment protection measures 12 Manufacturer Warranties 12 1 Quality Management System meets provisions of ISO 9001 2011 12 2 The manufacturer guarantees the compliance of the de tector with te...

Отзывы: