15
REDUCED GAS FLOW RATE SETTING FOR HOB TAPS
1.
Ignite the burner that is to be adjustment
and turn the knob to the reduced position.
2.
Remove the knob from the gas tap.
3.
Use an appropriately sized screwdriver to
adjust the flow rate adjustment screw. For LPG
(Butane-Pro pane) turn the screw clockwise.
For the naturel gas, you should turn the screw
counter- clockwise once.
“The normal length of a straight flame in the
reduced position should be 6-7 mm.“
4.
If the flame is higher then the desired
position, turn the screw clockwise. If it is
smaller turn anticolockwise.
5.
For the last control, bring the burner both
to higt-flame and reduced positions and check
whether the flame is on or off.
Depending on the type of gas tap used in your appliance the adjustment
screw position may vary.
To adjust your oven acc. to the gas type, make the adjustment for re-
duced flame carefully by turning with a small screwdriver as shown below
on the screw in the middle of the gas cocks as well as nozzle changes.
(Figure 3 and 4)
REDUCED FLAME GAS COCK ADJUSTMENT
1.
Please use driver with special head for removed and install nozzle
as (Figure 5).
2.
Please remove nozzle (Figure 6) from burner with special nozzle
driver and install new nozzle. (Figure 7)
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7