Cleaning and routine maintenance & Alarm function
Alarm function
1
16
Empty the water container
WARNING:
!
1.Hold and pull out the water container with two hands.
2.Tilt the water container, pour out the condensed water.
3.Insert the water container.
1.Empty the water container after each use, the programme will be paused and the “ ” icon
will flash if the water container is full during the drying process. After the container emptyed,
the dryer can be restarted by pressing
【
Start/Pause
】
button.
2.Do not drink the condensed water.
3.Do not use the dryer without the water container.
“
”
E32
“
”
E33
Empty
container
Dispiay
Reason
Solutions
Container is full
Water pump failure or water
level sensor failure
P
lease contact your
local service center
if the problem
persists
Humidity sensor failure
Temperature sensor failure
Filter is plug up or
environment
temperature
is too high
P
lease contact your
local service center
if the problem
persists
C
lean filter and
confirm the
ambient temperature
“ ”is flashing
“ ”is flashing
“
”
E30
Heater failure