Service Manual
Service Manual:
MSDW16012
- 12 -
10.
LP8 840 (VR01 / VR02) / LP8 440 (VR01 / VR02)
1.
ON/OFF button
5. Half load button
2.
Delay button
6. Program phase indicators
3.
Program indicators
4.
Program button
Wiring diagram:
See section 3
Optional Components:
Aquastop (inlet hose)
Hydraulic diagram:
See section 2
Error indication:
Display
Service Test
Follow the next steps to launch the test service:
- Connect the appliance to the power supply.
- Keep pressed the Program button [4]. The door must be open.
- Press and release ON/OFF button [1]. All leds from control panel start to blink.
- Once the door is closed, service test will start.
You can advance to the next step of the test by pressing the Program button [4],
except during water loading.