Operating instructions
(Translation of the original operating instructions)
VIROLINE
SMART
TEKA Absaug- und Entsorgungstechnologie GmbH, Millenkamp 9, D-48653 Coesfeld,
Tel.: +49 2541-84841-0, E-Mail: info
@teka.eu
, www.teka.eu
1
Страница 1: ...ng instructions Translation of the original operating instructions VIROLINE SMART TEKA Absaug und Entsorgungstechnologie GmbH Millenkamp 9 D 48653 Coesfeld Tel 49 2541 84841 0 E Mail info teka eu www teka eu 1 ...
Страница 2: ...2 Integration in the WLAN and app WiFi version 7 5 3 Attach the plug 10 6 Operating the system 11 6 1 Explanation of the operating elements 11 7 Maintenance 12 7 1 Reset to maintenance state 13 7 2 Replacing the microfilter mats 13 7 3 Recplacing the UV C lamp 14 8 Dismantling Disposal 15 9 Diagnostics and troubleshooting 15 10 List of spare parts 16 11 Technical data 16 12 EC declaration of confo...
Страница 3: ...n maintenance and repair of the device The operator must ensure that the operating personnel take note of these instructions Please read these instructions before operating the device and observe the safety precautions to avoid injury Store this manual in a safe place These instructions are to be regarded as a component of the product Adhere to all product notes Modifications or conversions that t...
Страница 4: ...on of the system elements Installation example Z Nr 20393701 Pos 1 Pos 2 Pos 3 Pos 4 Fan Microfilter mats 2 pieces UV C lamp Fastening eyelet Pos 5 Pos 6 Pos 7 Suction grille Exhaust grille Mains cable with plug BA_VIROLINE SMART_200921_EN 4 12 01 2022 ...
Страница 5: ...e explosive dust and gases hybrid mixtures glowing or burning substances gases water etc The device must not be operated in explosive zones 3 Safety instructions 3 1 Definition of the hazard symbols The device is constructed according to the state of the art and the recognised safety regulations Nevertheless during use threats to life and limb of the user or other persons may arise The impairment ...
Страница 6: ...aintained by a qualified electrician or under the direction and supervision of a qualified electrician Do not work on components if you are not sure that these are disconnected If necessary disconnect the device from the electric power supply and secure it against unauthorized restarting 4 Storage transport and installation of the device WARNING Risk of injury from tilting or unmounted components ...
Страница 7: ...t trucks and similar events Protect all supply lines from heat moisture oil and sharp edges 5 1 Electrical connection NOTICE Electric malfunction possible in cause of an incorrect power supply Pay attention to the admissible supply voltage Please observe the specifications on the type plate Connect the mains cable see chapter 2 1 to the power supply 5 2 Integration in the WLAN and app WiFi version...
Страница 8: ...ed app Smart Life Smart Living onto your terminal device Android https play google com store apps details id com tuya smartlife hl de Apple https apps apple com de app smart life smart living id1115101477 Start the App Create a new account A or attempt to perform the operation without creating an account B Add a new device Next choose to change WLAN WiFi BA_VIROLINE SMART_200921_EN 8 12 01 2022 ...
Страница 9: ...the opening A so that the control lamp of the inside built receiver starts to flash quickly As soon as the lamp starts to glow permanently you must tick Next Step on the terminal device 1 and press Next 2 As soon as the device has been recognised this is indicated on the terminal device The device can then be attached to the intended location BA_VIROLINE SMART_200921_EN 9 12 01 2022 ...
Страница 10: ...5 3 Attach the plug The supplied plug Ø6 mm must be attached to the opening A if not already done BA_VIROLINE SMART_200921_EN 10 12 01 2022 ...
Страница 11: ...i ON OFF switch App By means of this switch the device is switched on and off Alternatively the system can also be started using the app see chapter Commissioning When the device is switched off it is not disconnected from the power supply If the system does not switch on check whether this is because a timer is being used When disconnected from the power supply the system remembers the last opera...
Страница 12: ...s functionally equivalent to the original state CAUTION Hazards to the respiratory tracts are possible All maintenance work must only be carried out in well ventilated rooms and while wearing an appropriate respiratory mask We recommend respiratory protection half mask DIN EN 141 143 protection level P3 For all maintenance work ensure a cautious handling of filter elements and components in order ...
Страница 13: ... amount of accumulated dust and therefore cannot be determined beforehand CAUTION Whirling up dust is possible The microfilter mat is a disposable filter element Do not try to clean the filter element Release the protective grilles on both sides suction grille and exhaust grille see chapter 2 1 To do this release the 4 screw connections of both grilles Replace the microfilter mats with new ones On...
Страница 14: ...rs Use gloves Release the exhaust grille see chapter 2 1 To do this release the 4 screw connections Remove the microfilter mat There is another protective grille behind the microfilter mat Also release this Now carefully pull the UV C lamp out from its holder Insert the new UV C lamp Only use TEKA spare parts Otherwise the proper functioning of the unit is not guaranteed Mount the inner protective...
Страница 15: ...stem is functionally equivalent to the original state Repairs may only be carried out by TEKA personnel or after consultation with TEKA GmbH by the personnel authorised by the operator Adhere to the instructions in the chapter Safety instructions and Maintenance when carrying out any repairs If in doubt contact our TEKA service department Tel 49 2541 84841 0 E mail info teka eu Fault Cause Removal...
Страница 16: ...T WiFi Supply voltage V 230 230 Frequency Hz 50 50 Type of current Ph 1 1 Engine power kW 0 027 0 038 Air flow volume max m h 400 700 Protection class IP54 IP54 ISO class F F Width Depth Height mm mm mm 1000 290 290 1000 345 345 Weight kg 16 19 5 Sound pressure level dB A 43 43 Allowed ambient temperature C 5 to 35 during operations 10 to 40 during transport and storage Allowed max humidity 70 BA_...
Страница 17: ...ed above from the serial number A18200010011001 resp P39000010011001 on conforms to the following directives Machinery Directive 2006 42 EG Electromagnetic Compatibility 2014 30 EU This declaration will become void if the device is exposed to modifications that are not approved by the manufacturer in written form Authorized representative for the technical documentation TEKA Absaug und Entsorgungs...
Страница 18: ...yee confirms that he has been instructed regarding the following items Instruction completed Description of the device Operation and application of the device Explanation of the safety instructions Behavior in case of fire Explanation of the operation elements Change and dedusting of the filter elements Appropriate disposal Maintenance works Maintenance intervals Name of the employee legible Signa...
Страница 19: ...or check the degree of pollution 7 2 semi annually Replacing the UV C lamp 7 3 after 9000 operation hours this is absolutely necessary as the lamps lose intensity over time 14 2 General maintenance The described maintenances are independent from the demands of the system operations The operator is obliged to carry out repeated inspections and functional tests according to national regulations If n...
Страница 20: ...witch on the device Pay attention to extraneous noises or vibrations during the device s operation Check if the collection of the ambient air is sufficient Visual inspection 14 2 3 Electrical test of the electrical lines and earthing connections WARNING Danger arising from electricity The operator is responsible for ensuring that all work on electric components is carried out by authorised and qua...