IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
RELEASE DATE
8-14-17
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.tekaillumination.com • [email protected]
REFERENCE NUMBER
INS-2621-00
PINNACLE FLOODLIGHT™ (PNF)
Aiming
5. Lift out driver, then disconnect from fixture.
Hold onto lead from fixture, then install new
driver via quick disconnect.
Do not pull on connector or wiring. Handle
with care.
3. Remove optic by pulling gently and lift up.
4. Use .050” Allen wrench to loosen two (2) set
screws holding LED module. Gently lift LED
module and disconnect from fixture.
6. Install new LED module. Replace optic by lining
tabs with optic holder, then pressing down gently
until secured into place.
1.
Loosen two (2) captive screws on stainless steel
clamp rings using 5/32” Allen wrench until the
screws disengage from back plate.
2. Swing lens assembly open.
7. Replace optic by lining tabs with optic holder,
then pressing down gently until secured into
place.
8. Close swing assembly.
Tighten two (2)
captive screws on stainless steel clamp rings
using 5/32” Allen wrench. Do not overtighten.