4.2 Breakdown and Maintenance

Red light flashes

Green light flashes

Blue light flashes

END

Leakage

Protection

Creepage

Over

Voltage

Under

Voltage

Over

Current

Over

Temperature

0x0001

0x0002

0x0004

0x0008

0x0010

flash

flash

flash

flash

flash

1

2

3

4

5

Less voltage

protection

Over voltage

protection

Over temperature

protection

Over Voltage

protection

Solution

Relay is disconnected charging stops. The relay is cut off and the red light 

ashes. Power off and then on again.

Over voltage charging stops automatically , the relay is cut off, the red  light starts to 

ash.  Power off and then on again.

Under voltage charging stops automatically , the relay is cut off, the red  light starts to 

ash.  Power off and then on again.

If the maximum current is 2A higher than the chargers maximum 

charging stops automatically , the relay is cut off, the red light starts to 

ash. Power off and then on again.

When the temperature is higher than 85 °C, the charging will stop  automatically, the relay will be disconnected, the red light will start to 

ash, 

when the temperature drops below 85 °C  the relay will automatically 

reset and charging will begin automatically. When the temperature is 

between 75 ° C and 85 ° C, the control box will automatically lower one 

gear position. When the temperature is lower than 75 ° C, the gear 

position will automatically recover.

Condition

Display code

LCD

display

Status

indicator light

Status

indicator light

Malfunction and Maintenance

4.1 Maintenance

Regularly check charging cable for damage. 
Inspect charger casing to ensure the seals are intact and no physical 
damage exists.
Observe incoming lines to make sure no wire is damaged.

Содержание TS-EVC07-002

Страница 1: ...Teison Instruction Manual ...

Страница 2: ...Specification 6 1 3 Product List 7 1 4 Transportation and Storage 7 2 1 Safety tips 7 2 2 Installation guide 8 3 1 Charge preparation 11 3 2 Charging RFID 11 3 3 LCD display 12 4 1 Maintenance caution 13 4 2 Troubleshoot and Maintenance 14 4 3 Warranty Card 16 ...

Страница 3: ...RNING Please read the below safety guide before use WARNING Never use if charging cable is damaged The charger must be fitted by a qualified electrician using the appropriate RCB for the application A visual check for damage must be undertaken before each use This charger must only ever be used to charge electric EVs or hybrid vehicles PHEVs The charger must be installed in a well ventilated area ...

Страница 4: ... 10 32A 50 60Hz 7 8kw 5 3 7 0KG Energy Meter 5 2 8 2KG TYPE B MID certified 5 5 8 5KG Residual current protection Yes LCD screen 3pcs cards TYPE A 30mA DC6mA One charging socket Type 2 4 5M charging cable PCV0 for outdoor PC Wall mount Floor stand EN 61851 1 100000 Hours 2years IP67 30 50 C 5 95 without condensation 2000M Indoor Outdoor 398x324x120mm TS EVC11 002 S 380VAC 10 16A 50 60Hz 11kw TS EVC...

Страница 5: ...ing device must be installed by a qualified electrician Before first power up confirm with your installer that it is safe to use Make sure all cables are secure and the device is clean and is in a well ventilated area The charger cannot be installed in an area with possible flame or gas exposure Never allow children to touch the charger ...

Страница 6: ... 1 meter above ground mark hole position Drill holes in the wall 2 Install expansion screws A 4 Install the plate B to the back of the charger 5 Secure the charger on the fitted backplate Danger Installation must be carried out by a qualified electrician The electric shock would happen if don t install accord with operation procedure The electric shock or the serious hazard would happen if don t o...

Страница 7: ...tatus 3 3 LCD Display Prompt to connect your charging cable when it s in the standby status Users can choose three ways to stop charging 1 The charger will detect the cars battery is fully charged 2 Swipe the RFID card on charger charging will stop 3 Cut power to the charger After plug in follow on screen prompts Fault mode see page 14 CONNECTED Green light is on constantly Blue light is on consta...

Страница 8: ... maximum current is 2A higher than the chargers maximum charging stops automatically the relay is cut off the red light starts to flash Power off and then on again When the temperature is higher than 85 C the charging will stop automatically the relay will be disconnected the red light will start to flash when the temperature drops below 85 C the relay will automatically reset and charging will begi...

Страница 9: ...to factory for repair The CP of the charging cable is short circuited stop charging and cut power to the charger Have cable inspected by a qualified electrician If for whatever reason the red emergency stop button is pressed the charging will immediately stop Press again to resume charging Can not communicate with the meter for more than 5 seconds charging stops and the relay is cut off charging r...

Страница 10: ... Teison 17 ...

Отзывы: