4.2 Breakdown and Maintenance
Red light flashes
Green light flashes
Blue light flashes
END
Leakage
Protection
Creepage
Over
Voltage
Under
Voltage
Over
Current
Over
Temperature
0x0001
0x0002
0x0004
0x0008
0x0010
flash
flash
flash
flash
flash
1
2
3
4
5
Less voltage
protection
Over voltage
protection
Over temperature
protection
Over Voltage
protection
Solution
Relay is disconnected charging stops. The relay is cut off and the red light
fl
ashes. Power off and then on again.
Over voltage charging stops automatically , the relay is cut off, the red light starts to
fl
ash. Power off and then on again.
Under voltage charging stops automatically , the relay is cut off, the red light starts to
fl
ash. Power off and then on again.
If the maximum current is 2A higher than the chargers maximum
charging stops automatically , the relay is cut off, the red light starts to
fl
ash. Power off and then on again.
When the temperature is higher than 85 °C, the charging will stop automatically, the relay will be disconnected, the red light will start to
fl
ash,
when the temperature drops below 85 °C the relay will automatically
reset and charging will begin automatically. When the temperature is
between 75 ° C and 85 ° C, the control box will automatically lower one
gear position. When the temperature is lower than 75 ° C, the gear
position will automatically recover.
Condition
Display code
LCD
display
Status
indicator light
Status
indicator light
Malfunction and Maintenance
4.1 Maintenance
Regularly check charging cable for damage.
Inspect charger casing to ensure the seals are intact and no physical
damage exists.
Observe incoming lines to make sure no wire is damaged.