Suction equipment

hepair 6000

19

maintenance and care

TEINNOVA stocks spare parts for all the machine’s components as well as consumables for all the 
maintenance tasks shown in this manual.

If you need any spare part or consumable, please contact TEINNOVA Customer Service at 
+34 941 44 50 56.

Spare Parts:

Содержание TECAI hepair 6000

Страница 1: ...Suction equipment hepair 6000 user manual EN original manual translation...

Страница 2: ...tegy We offer the option of providing companies with specific training in the use of our equipment and to educate their operators so they provide the best service and thus contribute to the success of...

Страница 3: ...hepair 6000 3 contents symbols used safety warnings conditions of use know your machine accessories and related equipment operating instructions 5 23 6 23 7 23 8 23 9 23 11 23 transport 15 23 16 23 ma...

Страница 4: ...Suction equipment hepair 6000 4 contents waste management technical specifications guarantee conditions declaration of conformity CE 20 23 21 23 22 23 23 23...

Страница 5: ...tructions given are not followed properly Make sure you read all the instructions in the Safety information section WARNING This symbol warns you of a potentially dangerous situation that could result...

Страница 6: ...ipment in an explosive atmosphere The front and rear of the machine have fan air outlets leave enough space for proper air flow Do not use the machine without filters If there is a blockage in the suc...

Страница 7: ...as been designed and manufactured for the suctioning of air conditioning ducts and should not be used in other types of ducts It has a 5 metre long hose that by means of telescopic supports can be ada...

Страница 8: ...mponents 1 Main Filter H13 2 Pre filter F7 3 Air expulsion grill 4 Acoustic indicator 5 Mains supply connection 6 Wheel with brake 7 Wheel 8 ON OFF switch 9 Transport handle 10 Wheels for horizontal u...

Страница 9: ...Code 110HEP017 Rigid 400 duct adapter module Quick close clamp 400 Reducer from 400 to 300 Optional accessories Adapter module between the HEPAIR 6000 and the duct to be suctioned Code 110HEP015 Quick...

Страница 10: ...and ABS Efficiency 99 95 Code AC3101317 Filter H13 Tube 5 m long 400 Tube 5 m long 300 Flexible tube made of plasticised PVC with self extinguishing textile PVC reinforcement and with a galvanised ste...

Страница 11: ...nd of the suction hose over the HEPAIR 6000 air intake It should be positioned as shown in the following image Position the quick close clamp and tighten it so that the suction hose and suction cleane...

Страница 12: ...It should be positioned as shown in the following image Position the quick close clamp and tighten it so that the suction hose and suction cleaner are securely joined Position the duct adapter module...

Страница 13: ...nection is done with a clockwise turn of the blue connector as shown in the image To turn on the machine press the ON OFF power switch as shown in the image Connection to mains power Turning on your H...

Страница 14: ...achine press the ON OFF switch as shown in the image Turning off your HEPAIR 6000 7 Unplug the machine from the mains using the power cable and then disconnect it from your HEPAIR 6000 This is done wi...

Страница 15: ...can be transported in a vertical or horizontal position resting on the wheels built into the handle The machine must be firmly attached to the chassis of the vehicle and the front wheel brakes must b...

Страница 16: ...possible Keep the equipment in a place protected from the weather Replace or clean the filters after prolonged use Clean the machine after each job to keep it in perfect condition maintenance and care...

Страница 17: ...and unplugged To turn off the machine press the ON OFF switch as shown in the image Maintenance operations Changing the filters 1 Unplug the machine from the mains using the power cable and then disco...

Страница 18: ...IR Once the filters have been cleaned or replaced they must be put back in position and the filter cover closed as shown in the image Ensure that the pressure seals are properly fixed Remove the filte...

Страница 19: ...re TEINNOVA stocks spare parts for all the machine s components as well as consumables for all the maintenance tasks shown in this manual If you need any spare part or consumable please contact TEINNO...

Страница 20: ...ollection points for recycling Do not dispose of electrical equipment in the trash We recommend that electrical tools and accessories are subjected to an environmentally friendly recovery process Plea...

Страница 21: ...ge 1 Filtering stage 2 Particle capture Motor power Current drawn Noise level Dimensions Weight without filters Weight with filters HEPAIR 6000 Specifications 220V 50 60Hz 110V 50 60Hz 750 650 1300 62...

Страница 22: ...oint 2 the transport both collection at the customer s facilities and return of the product will be borne by the customer TEINNOVA reserves the right to overrule the application of the guarantee when...

Страница 23: ...ertifies that the machine model described above complies with all the essential requirements of the following directives Machinery directive 2006 42 CE Directive 2014 30 EU on electromagnetic compatib...