© by WilTec Wildanger Technik GmbH
Item 55550
Page 4
01 2022
-1
5.
Do not place the pump directly in the pond floor mud, place it on a raised surface.
6.
Connect the pump with the controller of four core wire
(Fig.
1, 1),
lock the nut
(Fig.
1, 2).
7.
Connect the power supply of the controller.
Controller operation instructions
1. On/off
Plug in the device and touch
to switch the pump on and off.
If the device is not operated for a long time, please unplug it.
2. Flow rate adjusting
Press
or
to adjust the flow rate; the device disposes of 10
levels, and
the display screen will show “SP01”–“SP10.” For detailed information please refer
to the parameter list:
Power supply
Level
Power
(W)
Flow rate
(
ℓ
⁄
h
)
Flow head
(m)
220–240
V/50
Hz
1
80
13,000
2.8
2
100
14,000
3.4
3
130
15,500
4.0
4
160
17,000
4.5
5
200
18,000
5.1
6
240
19,000
5.8
7
285
20,500
6.5
8
335
22,000
7.2
9
380
23,500
7.8
10
450
26,000
8.5
3. Feeding mode
Press
for 3
s to enter the time delay start mode, and the screen will show “FD10.” The device will
start to work after 10
min. Again press
for 3
s to quit the feeding mode.
4. LOCK function
Long press
to lock the keys, and the screen will show “LOC.” Long press
to unlock the keys.
5. Automatic memory function