background image

 

© by WilTec Wildanger Technik GmbH 

 

Item 50337, 50338, 50248, 50249, 50283

 

Page 5 

 

http://www.WilTec.de

 

http://www.aoyue.eu

 

 

 

05 2022

-1

 

http://www.teichtip.de

 

 

parts subjects to wear (propeller, sealing flange) do not fall under warranty.

 

 
 

Hints for maintenance

 

 

The pond motor pump is a maintenance-free and a practice-proven quality product that was subjected 
to rigorous final inspections. For a long working life and continuous operation, we recommend regular 
checking and proper care.

 

 
 

Maintenance and cleaning

 

 

Overload protection:

 

 

The pump has an integrated overheat protection. After the pump is stopped it must cool down for a while 
due  to  the  overheat  control  device,  before  it  runs  again.  In  case  it  does  not  run  again  by  itself,  the 
following checks shall be conducted:

 

 

Has the pump cooled down sufficiently due to the overheat protection after being stopped?

 

Is the water supply sufficient?

   

>

 

Improve the water supply!

 

Is the filter clogged?

 

 

 

>

 

If necessary, rinse the filter!

 

Is there dirt in the pump housing?

 

>

 

Perform cleaning!

 

Is the hose or the pipe clogged?

 

>

 

Clear the hose/pipe!

 

Is the hose broken, too long?

   

>

 

Check, replace, shorten!

 

 
 

Technical specifications

 

 

Model

 

(Item №)

 

Dimensions

 

(

)

 

Motor 

type

 

Current 

supply

 

Power 

consump-

tion 

(W)

 

Max. deliv-

ery head

 

(m)

 

Max. flow 

rate

 (

h

)

 

Hose con-

nection Ø

 

(

)

 

CQB-2003

 

(50337)

 

193 × 99 × 

99

 

Synchro-

nous

 

230

 

V / 

50

 

Hz

 

35

 

2.0

 

2300

 

19 (¾″)

 

25 (1″)

 

CQB-2503

 

(50338)

 

35

 

2.5

 

2400

 

CQB-2000

 

(50248)

 

175 × 105 × 

100

 

35

 

2.0

 

2400

 

21 / 25

 

CQB-2500

 

(50249)

 

45

 

2.4

 

2700

 

 
 

Maintenance and cleaning of the pump

 

 

Procedure

 

 

1.

 

Disconnect the pump!

 

2.

 

Pull the front filter away from the motor body. Now you can see the motor body.

 

3.

 

Pull the impeller out of the motor body and clean everything by using a sponge with water.

 

 

Re-assembly

 

 

1.

 

Introduce the rotor/impeller assembly carefully in the motor housing/pump body. Make sure that 
the rotor is properly placed and can rotate freely.

 

2.

 

Connect the pump housing with the filter basket and place them onto the motor body. Then the 
pump is ready to use.

 

 

Содержание SUNSUN CQB-2003

Страница 1: ...and follow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data c...

Страница 2: ...up to date mistakes cannot be entirely avoided If you should find a mistake or wish to make a suggestion for improvement we look forward to hearing from you Send an e mail to service wiltec info or u...

Страница 3: ...gulations Use the device exclusively according to the intended purpose stated in the instructions for use You are responsible for the safety of the working environment If the cable or the plug is dama...

Страница 4: ...pump is ready for use Installation Notes The pump must be installed under water Make sure that moisture or water never reaches the mains connection The pump is to be installed as follows in a fixed po...

Страница 5: ...ent Improve the water supply Is the filter clogged If necessary rinse the filter Is there dirt in the pump housing Perform cleaning Is the hose or the pipe clogged Clear the hose pipe Is the hose brok...

Страница 6: ...http www WilTec de http www aoyue eu 05 2022 1 http www teichtip de Exploded views CQB 2000 2500 50248 50249 Name Name Name 1 Front filter 5 Rubber bearing 9 Big filter 2 Impeller cover 6 O ring 2 10...

Страница 7: ...p www teichtip de CQB 2003 2503 50337 50338 Name Name Name 1 Fountain head 7 Front filter 13 Rubber feet 2 Press nut 8 Impeller cover 14 Big filter 3 Riser stem 9 Rubber bearing 15 Outlet nut 4 Connec...

Страница 8: ...and other European countries with a separate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold...