background image

 

© by WilTec Wildanger Technik GmbH 

 

Item 50982, 51192

 

Page 3 

 

http://www.WilTec.de

 

http://www.aoyue.eu

 

 

 

02 2022

-1

 

http://www.teichtip.de

 

 

Introduction

 

 

Thank you for purchasing this quality product.

 To minimise the risk of injury we urge that our clients 

take some basic safety precautions when using this device. Please read the operation instruc-
tions carefully and make sure you have understood its content.

 

Keep these operation instructions safe.

 

 
 

Unpacking

 

 

If the article is visibly damaged, please contact the vendor.

 

 
 

Safety regulations

 

 

 

For your own safety, please contact an electrical specialist in case of questions and problems.

 

 

Do not connect the power supply until all parts are installed.

 

 

Only plug the pump in a power receptacle with ground contact. This type of outlet must have 
been set up according to the respective national directives. Ensure that the PE conductor goes 
all the way to the pump.

 

 

Make sure that the voltage in the pump is the same as the actual power supply.

 

 

Electrical installations on garden ponds must correspond to the national and international instal-
lation directives.

 

 

Only operate the pump if there is no one in the water.

 

 

Do not carry or pull the pump by the connecting cord. The cable must not get in contact with 
heat or grease; it must not touch sharp angles.

 

 

The pump may not be operated if the cable or the casing are defective.

 

 

Never transport any liquids other than water.

 

 

 Attention: 

The pump will automatically stop working if overloaded or running without wa-

ter.

 

 

The controller is not water-proof; put it in a dry and well-ventilated place.

 

 

Do not inspect the electrical parts of the pressure pond filter in a wet or damp environment or 
when you are wet yourself, and protect it from direct sunlight.

 

 

Install this device in a safe location so that nobody can step on, fall over, or damage the cable.

 

 

Disconnect the power plug before cleaning, and use only a damp cloth for cleaning. Avoid using 
cleaning agents and make sure that no liquid enters the electric parts of the pump.

 

 

The electric parts of the device contain no parts that can be inspected or serviced by the user. 
Leave the maintenance, adjustment, and repair to qualified technical personnel. In case of un-
authorised intervention, the 2-year warranty is no longer valid!

 

 
 

Use

 

 

Applies to ponds, rockery, aquarium tanks, and seafood tanks.

 

 
 

Features

 

 

 

Multi-function intelligent control, can adjust flow and power

 

 

New electronic frequency conversion technology, energy saving 60

 

%

 

 

Centrifugal impeller design, improves H-max and output

 

 

Super silence, usable both in fresh and sea water

 

 

New and generous design, rotary handle, easy to carry

 

 

Rotary footings, can work both vertical or horizontal

 

 

Содержание SUNSUN Adjustable SuperECO CET-15000

Страница 1: ...llow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can dif...

Страница 2: ...service wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch...

Страница 3: ...ct with heat or grease it must not touch sharp angles The pump may not be operated if the cable or the casing are defective Never transport any liquids other than water Attention The pump will automat...

Страница 4: ...ems Installation 1 Notify your dealer immediately if there are external damages 2 Compare the voltage and frequency of your electrical circuit with the data on the model plate these data must correspo...

Страница 5: ...ch START STOP control the pump switch Attention please cut off the power if you do no use the pump for a long time Adjust the gear level Touch DOWN or UP to adjust pump gear Consult the detailed perfo...

Страница 6: ...With the correct gear you need to press down until the buzzer sounds twice The pump is now locked To unlock proceed in the same way Automatic memory function When the controller power is cut off sudde...

Страница 7: ...ervoltage display Abnormal Check voltage Maintenance cleaning Please clean the filter casing impeller rotor and shaft part regularly Please cut off the power before you clean it 1 Turn and take off th...

Страница 8: ...h the controller unit Re link to the controller unit The controller is damaged Change the controller Pump noise Dirt inside Clean pump Shaft break or wear Change shaft Pump water short age Damage of t...

Страница 9: ...r European countries with a separate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but...