8. Keep hands away from rotating parts.
9. Make sure the trimmer bit is not contacting the workpiece before the switch is turned on.
10. Before using the tool on an actual workpiece, let it run for a while. Watch for vibration or
wobbling that could indicate improperly installed bit.
11. Be careful of the trimmer bit rotating direction and the feed direction.
12. Do not leave the tool running. Operate the tool only when hand-held.
13. Always switch off and wait for the trimmer bit to come to a complete stop before removing the
tool from workpiece.
14. Do not touch the trimmer bit immediately after operation; it may be extremely hot and could
burn your skin.
15. Do not smear the tool base carelessly with thinner, gasoline, oil or the like. They may cause
cracks in the tool base.
16. Use trimmer bits of the correct shank diameter suitable for the speed of the tool.
17. Some material contains chemicals which may be toxic. Take caution to prevent dust inhalation
and skin contact. Follow material supplier safety data.
18. Always use the correct dust mask/respirator for the material and application you are working
with.
INSTALLATION INSTRUCTION
Always be sure that the tool is
switched off and the battery cartridge is
removed
before carrying out any work on the tool.
WARNING
INSTALLING OR REMOVING TRIMMER BIT
Do not tighten the collet nut without
inserting the bit. The collet cone may break.
NOTE
Insert the trimmer bit all the way into the collet cone.
Tighten the collet nut with the wrench or tighten the collet nut securely with the two wrenches. To
remove the bit, follow the installation procedure in reverse.
INSTALLING OR REMOVING THE TRIMMER BASE
1. Open the lock lever of the trimmer base, then insert the tool into the trimmer base aligning the
groove on the tool with the protrusion on the trimmer base.
2. Close the lock lever.
3. To remove the base, follow the installation procedure in reverse.
INSTALLING OR REMOVING THE PLUNGE BASE
Optional accessory
1. Open the lock lever of the
plunge base, then insert
the tool
into the plunge base all the way aligning the groove
on the tool
with
the protrusion on the plunge base.
2. Close the lock lever.
3. To remove the base, follow the installation procedure in
reverse.
1. Lock lever
1