Operation model TFW 160-2S
Connect the cabinet to a socket and turn on the switch on the control panel (POWER), see fig. 2.1.
Fig. 2.1
When the cabinet is turned on, the display will show the current temperatures in the cabinet’s two
chambers.
Display set temperature:
Press this key and the display will flash the set temperature for the upper chamber.
After 5 seconds the thermostat will return to normal reading.
Press this key and the display will flash the set temperature for the lower chamber.
After 5 seconds the thermostat will return to normal reading.
Set new temperature:
Press this key and the display will flash the set temperature.
Every subsequent press on this key will lower the setting by 1 ºC, from 12 ºC to 5 ºC and
will start over again after that.
When the required temperature is reached, wait for 5 seconds and the thermostat will
return to normal reading.
Press this key and the display will flash the set temperature.
Every subsequent press on this key will lower the setting by 1 ºC, from 18 ºC to 12 ºC
and will start over again after that.
When the required temperature is reached, wait for 5 seconds and the thermostat will
return to normal reading.
Indicator lamps:
Control lamp ”Run” will turn on when the compressor is running.
Internal light:
Press this key to turn on/off the internal light.