Legacy 6000
98-05053 R2
35
input lines for sensors are established on the
Sensor Settings
page.
Secondary Sensor options include:
Flowmeter
•
Pressure digital
•
Pressure analog
•
granular
•
Shaft
•
injection
•
to access the sub-settings, locate the two
Sub-Settings
softkeys on the right side
of the screen. use the two softkeys to toggle between the screens. Refer to table
2-16 for a description of the sub-settings. when the primary settings and param-
eters have been selected, press the
Forward Arrow
softkey to advance to the next
Channel Setup
page.
Figure 2-29: Secondary Sensor/Sub-Settings
Table 2-16: Secondary Sensor Sub-Settings
settings
description
input
Defines digital and analog sensors. Sensor inputs A-D are digital (Flowmeter and
slot sensors) and sensors e-F are analog (pressure).
Sensor Name
used to label a particular sensor or monitor. this information is not stored in the
Channel and is used for messaging to the user only.
dual warning%
Defines the maximum acceptable % difference between the primary and secondary
sensor outputs before the operator is warned.
dual warning delay
Defines the time that the primary and secondary sensor outputs can exceed the
dual warning % before initiating the alarm.
Forward Arrow
softkey (F6)
Initial-Settings
softkey (F9)
Sub-Settings
softkey (F10)
Содержание Legacy 6000
Страница 1: ......
Страница 15: ...Chapter 1 Introduction 10...
Страница 51: ...Chapter 2 System Overview 46...
Страница 81: ...Chapter 3 Product Application Setup 76...
Страница 125: ...Chapter 5 System Tools 120...
Страница 149: ...Chapter 7 EXT 144...
Страница 150: ...Legacy 6000 98 05053 R2 145 Appendix A Channel Favorite Set tings...
Страница 151: ...Appendix A Channel Favorite Settings 146...
Страница 152: ...Legacy 6000 98 05053 R2 147...
Страница 153: ...Appendix A Channel Favorite Settings 148...
Страница 159: ......