TeeJet 744A Скачать руководство пользователя страница 8

7

98-70025 R2 EN-US

Product

®

ChApter 2 - InStAllAtIon

Mounting Bracket

1.  Make sure all switches on the 744A Sprayer Control are turned to 

the “Off” position.

2.  Determine the best location for the 744A Sprayer Control in the 

vehicle cab according to the following guidelines:

•  pressure gauge should be readily visible
•  switches should be within easy reach
•  controller bracket should rest on a flat surface
•  12 volt DC power source must be accessible (maximum draw 10 

amps)

3.  Determine the proper routing for power cables and pressure tube:

•  away from operators’ movement area
•  away from moving parts
•  away from sharp objects

4.  Install the mounting bracket using ¼” (6.4mm) drill, machine 

screws, nut, washers, and lock washers as illustrated below. Attach 

the control housing assembly to the mounting bracket using the 

console adjusting knobs and washers.

Figure 6: Mounting Bracket

output Control Cable

Cut a 1.0” (3.0 cm) diameter opening used to feed the output control 

cable from the interior of the tractor cab to the boom control valves. 

Make sure the hole has no burrs or sharp edges that could damage the 

wires.

744A-3 Unit

6 wires from the output cable are used to control a three-section boom.

•  Orange (Right) Yellow (Center) Green (Left) – connect to 

144A Valves. When using a *344AEC Ball Valve, connect to the 

white wire.

•  **Black – connect to other terminal on 144A Valves. When using 

the *344AEC Ball Valve, black is not connected.

•  Red and Brown – connect to red and black wires on the Regulator 

Valve (244, 344AE-PR, or 344AE-RL).

*When using 344AEC DirectoValve® Ball Valves, connect black wire(s) 

and red wire(s) using the Valve End and Battery End Cables 

(supplied only when Ball Valve Kits are purchased) to an 

uninterrupted power supply such as the battery.

**The black ground wire for the control cable is not supplied with 

connectors attached. The T-Tap connectors are supplied 

separately and should be attached as per Figure 7.

WARNING!: Do not plug the control cable into the control box until it 

has been fully connected to the control valves. Doing so may 

allow the unconnected leads to short out.

Figure 7: T-Tap Connector Assembly

Step A

Step B

Step C

To Terminal of

144 Directo Valve

Ball

Valve

Connector

Input power Cable

The Input Power Cable consists of three wires. The red wire should 

be connected to a 12 Volt power supply within the cab of the vehicle 

(i.e., ignition switch). If the power source is located outside of the 

cab, the power cable should exit the cab through the same 1.0” (3.0 

cm) diameter hole as the output control cable. The blue wire should 

be connected to the headlight system of the tractor. This can be 

accomplished by connecting the blue wire to the auxiliary terminal 

of the headlight switch or by splicing into the wire connected to the 

headlight. The black wire is the negative lead and should be connected 

to a good chassis ground.
Plug the input power cable into the power cable socket on the back of 

the 744A console. Turn the vehicle ignition switch to the “Run” position. 

If the wiring has been connected properly, the boom section indicator 

lights should illuminate when the boom section switches are toggled. 

The gauge light should appear when the headlights are illuminated.

pressure Gauge

The tubing for the pressure gauge is supplied as part of the wiring 

harness. To avoid chemical leakage into the vehicle cab, the tube 

coupler should be installed  outside of the vehicle cab. If a gauge 

isolator is used with the system, it should be installed in place of the 

coupler, also outside of the vehicle cab.
The pressure gauge should be checked for accuracy each season. 

If the unit is equipped with a liquid-filled gauge and it does not read 

accurately, the gauge may need to be vented. To vent the gauge, 

remove the four screws in the back of the sprayer control housing and 

lift off the back. The rear of the gauge will be exposed. To vent the 

gauge, clip off the nib of the rubber plug in the back of the gauge or 

puncture it with a needle. Once the gauge has been vented, do not 

store the sprayer control on its back as this may cause a loss of fluid 

from within the gauge. If further inaccuracy is suspected at 0 PSI and 

a gauge isolator is being  used, the isolator line may need to be bled 

according to the instructions furnished with the gauge isolator.

Содержание 744A

Страница 1: ...744A Sprayer Control U s e r M A N U A L...

Страница 2: ...SUMED IN NO EVENT SHALL TEEJET TECHNOLOGIES BE LIABLE FOR ANY LOSS OF BUSINESS LOSS OF PROFIT LOSS OF USE OR DATA INTERRUPTION OF BUSINESS OR FOR INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES O...

Страница 3: ...ith Solenoid or Ball Valves Manual spray controller in a compact package Liquid filled 100 PSI or 300 PSI pressure gauge Lighted pressure gauge for night use Heavy duty switches with LED indicators Av...

Страница 4: ...k Shut Off Line Strainer Diaphragm Pump Throttling Valve To 744A Controller Jet Agitatior Figure 4 Plumbing Diagram Centrifugal Pump and Self Cleaning Strainer To 744A Controller Throttling Valve Thro...

Страница 5: ...60 50000 1 4 External Tooth Lock Washer 2 9 60 50003 1 Bolt Steel Zinc Plated 2 10 60 50001 Flat Washer Steel Zinc Plated 2 11 60 50009 Lock Washer Steel Zinc Plated 2 12 350 0062 Hex Nut Steel Zinc P...

Страница 6: ...External Tooth Lock Washer I 60 50003 1 Bolt Steel Zinc Plated J 60 50001 Flat Washer Steel Zinc Plated K 60 50009 Lock Washer Steel Zinc Plated L 350 0062 Hex Nut Steel Zinc Plated M 67 20001 Male C...

Страница 7: ...50024 Front Housing 4 64 50031 Lens Gauge 5 51 20008 100 psi Liquid Gauge 51 20002 300 psi Liquid Gauge 6 60 50019 Square Nut 2 Req d 7 01 50007 Circuit Board 8 32 50010 Toggle Switch 9 350 2610 Plast...

Страница 8: ...low the unconnected leads to short out Figure 7 T Tap Connector Assembly Step A Step B Step C To Terminal of 144 Directo Valve Ball Valve Connector Input Power Cable The Input Power Cable consists of...

Страница 9: ...lve Pipe Nipple Optional Isolator Kit Tube Insert Tube Nut Tube Insert Gauge Elbow Tube Coupling Tube Nut Tube Nut Tube Nut Tube Insert Tube Insert Chapter 3 Maintenance Routine Procedures Several rou...

Страница 10: ...ay controller in a compact package Liquid filled 100 PSI or 300 PSI pressure gauge Lighted pressure gauge for night use Heavy duty switches with LED indicators Available in a variety of kit forms usin...