12
www.teejet.com
844E Sprayer Control
Console Step 3 - Power Connection
Locate the power cable that has a black connector on one end and two battery terminal rings on the other. Extend
the battery terminal ring end of this cable from the cab to the battery.
NOTE: Some tractors use two 6 Volt batteries as a power source. Make sure there are a total of 12 Volts
delivered to the controller by connecting to the (+) terminal on one battery and the (-) terminal on the other
battery. Reliable operation of the 844 Sprayer Control depends on a clean power supply. Ensure this by
connecting the power cables directly to the battery and not to another power source.
Connect the battery terminal rings to the battery posts, making sure that the positive (red) and negative (black)
wires correspond with the polarity of the battery terminals.
NOTE: The power cable is designed to provide the simple addition of a remote master boom switch in a
convenient location (i.e. on the throttle, gear shift, or floor switch). To install a remote boom switch, simply
install a switch to the brown wire in the power cable. The switch should be rated to handle the total current
used by all boom section valves combined. If installed, the remote master switch will operate in series with
the boom switches on the console.
Connect the battery cable to the power cable lead that extends from the main cable.
Test the installation by pressing the
key once to turn the 844 console on. If the display shows information, you
have wired the power correctly.
NOTE: The TeeJet 844 Sprayer Control has an automatic power down feature. With the master boom switch
in the “off” position, the 844 will automatically shut down after 10 minutes of no inputs. This prevents
possible battery drainage. To turn the console “off” with the Master Switch located in the “off” position,
press and hold the
key while pressing the
key once, and then releasing both keys. The console
will shut down providing no other keys are pressed.