M
SECOSTEEL-PRO 30R290
-01
Manual _ITA_UK_DE_FR_ES_DK - 23/04/2021
29
EN
SET HUMIDITY %:
Press the keys to set the desired set point value.
HOUR COUNTER:
Press the HOURS button to view the operating hours.
PUMP
:
Press the PUMP button to force emptying.
If there is no water in the pump, do not force the emptying or the pump will be damaged.
Normally the pump is automatically started/stopped by the pump's internal sensor.
4.3
Alarm list
PROBLEM
PROBABLE CAUSE and CORRECTIVE ACTIONS
+
“F
u
LL”
Full tank or pump in alarm.
Full tank: the alarm is automatically reset by emptying the tank.
Pump in alarm: check the electrical connection of the pump and that no restriction is
present on the delivery pipe. Otherwise, please contact the service centre for the
replacement
.
+ “Lo t”
It occurs when the ambient temperature is too low. To restore, put the unit in an
environment above 10 ° C, if it is not reset, set it to OFF with the POWER button and
disconnect the power supply.
+ “Pro
b
”
Malfunction of the humidity probe. The unit continues to operate in continuous mode
without humidity control.
Please contact the service centre for the replacement
+ “Pro
3
”
Temperature probe malfunction. In any case, the device continues to operate. Please
contact the service centre for the replacement
.
+ “
dEFr
”
Defrost thermostat malfunction
Dehumidifier goes to stand-by. Please contact the service centre for the replacement
.
4.4
Condensate pump connection (optional)
The device can optionally be equipped with a condensate drain pump. (Only for prepared versions)