4
59
TO EMPTY THE WATER CONTAINER DO THE FOLLOWING
Do not move the unit. Drastic movements can cause water leakage.
Switch off the unit and remove the plug from the wall outlet.
Place a pan or appropriate tray on the floor underneath the permanent drain
tube.
Remove the rubber plug from the drain tube and let the water run out. (± 0.5
litres).
Replace the rubber plug, put the plug into the wall outlet, and switch on the
unit. The warning light should be off.
G
(DIS)CONNECTING THE INDOOR AND OUTDOOR UNIT
(FOR QUALIFIED PERSONNEL)
DISCONNECTING
Switch off the unit, remove the plug from the mains and leave it idle for at
least 30 minutes.
Open the cabinet cover for quick connector shielding
L
.
Disconnect the electric cable.
Disconnect the drain tube.
Remove the metal brackets which are holding the tubes and wire.
Remove the isolation material from the connectors.
Disconnect the refrigerant tubes using the spanners
O
provided. The
terminals are fitted with automatic self-sealing valves to prevent the
refrigerant from leaking. Loosen the nuts quickly, so the seal is made
promptly. During the operation take extreme care not to break or bend the
refrigerant tubes.
Screw the protection caps for the connectors
R
onto the ends of the
refrigerant tubes connectors.
8
7
6
5
4
3
2
1
5
4
3
2
1