background image

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

1MN0048 REV. 0 

 
 
 
 
 
 

 

operates with ISO9001:2008 certified quality system

 

 

 

 

 
 
 

 

http://www.tecsystem.it 

 

 

R. 1.0 16/09/13 

 
 
 
 

 

 

                                                          

“Translations

 

of

 

the

 

original

 

instructions”

 

   ENGLISH

 

TECSYSTEM S.r.l.

 

20094 Corsico (MI) 

Tel.: +39-024581861 

Fax: +39-0248600783 

VRT300 SERIES

 INSTRUCTION MANUAL 

Содержание VRT300 Series

Страница 1: ...ISO9001 2008 certified quality system http www tecsystem it R 1 0 16 09 13 Translations of the original instructions ENGLISH TECSYSTEM S r l 20094 Corsico MI Tel 39 024581861 Fax 39 0248600783 VRT300...

Страница 2: ...NUAL IS VALID AND COMPLETE FOR THE VRT300 AND VRT300 U VERSIONS PAGE 1 SAFETY REQUIREMENTS 3 2 ACCESSORIES 4 3 TECHNICAL SPECIFICATIONS 5 4 FRONT PANEL 7 5 INSTALLATION 8 6 ELECTRICAL CONNECTIONS 9 VR...

Страница 3: ...0 and never touch with wet or humid hands during storms If any liquid penetrates the control unit disconnect it immediately and contact technical service CLEANING Disconnect the power cable before cle...

Страница 4: ...3 2 Supply and relay terminals 3 poles pitch 5 Code 2PL0367 1 motor line terminal 6 poles pitch 5 Code 2PL0372 1MN0030 REV 2 The above terminals are optional according to the configuration purchased A...

Страница 5: ...max Connections on extractable terminal blocks OUTPUTS 1 fault sensor or operating failure FAULT relay SPDT Output relay with 5A 250Vac res COS 1 contacts 3 M1 M2 M3 outputs 250Vac max 10 5A max 50 6...

Страница 6: ...C Humidity 90 non condensing Housing NORYL 94 _V0 Absorption 4VA max Electronic protection only on customer s request Polycarbonate IP65 front DISPLAY AND DATA MANAGEMENT LED s alarm undercurrent over...

Страница 7: ...red 15 M1 motor in over current LED red 5 M3 motor in under current LED yellow 16 Current variation LED yellow 6 M2 motor in under current LED yellow 17 Fans local management LED red 7 Fixing block 18...

Страница 8: ...eet 2 1 3 1MN0063 REV 0 1 Control unit 2 Panel hole dimensions 0 8mm tolerance 3 Identification label Fix the unit securely with the blocks supplied 1 2 3 4 1MN0008 REV 0 1 Control unit 3 Fixing screw...

Страница 9: ...signal 2 Remote enabling contact ENABLE 5 Fan line supply 250Vac 10 15 amp max 50 60Hz 3 Control unit supply 230 Vac 10 50 60 Hz 4VA Note with the power to the unit ON the FAULT relay switches contact...

Страница 10: ...AULT relay fault signal 2 Remote enabling contact ENABLE 5 Fan line supply 250Vac 10 15 amp max 50 60Hz 3 Control unit supply 12Vac dc 10 4VA Note with the power to the unit ON the FAULT relay switche...

Страница 11: ...W TO CHECK THE ALARM STATUS Running LED OFF no ventilation activation control Running LED ON REMOTE or LOCAL ventilation activation Over and under current LEDs OFF motor operating correctly Over curre...

Страница 12: ...lt 5 7 Motor start for automatic calibration CAL LED ON To perform the automatic calibration all motors must be connected as per final configuration At the START the motors are switched ON for 60 seco...

Страница 13: ...M1 M2 M3 under current yellow LED ON Check the condition of the fans the cables and the supply Re program the device All the LEDs are flashing Memory error press RESET and repeat the programming proc...

Страница 14: ...14 VRT300 SERIES TECHNICAL INFORMATION ufficiotecnico tecsystem it COMMERCIAL INFORMATION info tecsystem it PRODUCT INFORMATION CATALOGUES DOWNLOAD CONTROL UNIT MANUALS ACCESSORIES USEFUL CONTACTS...

Отзывы: