7. GENERAL TROUBLESHOOTING
If you still experience problems after trying the
solutions presented here, contact AMPRO Technical
Support.
Design and product specifications are subject to
change without prior notice.
Symptom
Possible Cause
Possible Action
No output or fog machine
is spitting fluit.
Incorrect fluid
Clean thoroughly with Ampro FCQ.
For full instructions, see Fogger
Maintenance. Refill with Ampro
water-based fog fluid.
Blocked pipe ar falling part.
Contact Customer Service.
Circuit breaker or fuse keeps
blowing.
Excessive load on the circuit.
Make sure that the total load does
not exceed 80% of the breaker or
fuse rominal current.
Short circuit along the power
lines.
Check the power lines and power
cords.
Product does not power up.
No energy on power outlet.
Check power outlet
Change to another outlet
Loose of damaged power cord.
Check the power cord.
Blown fuse.
Replace blown fuse with a good
one of the same type and rating.
Internal problem.
Send product for repair.
Product stops pumping/Loud
noise.
Low/No fluid.
Refill product with fluid.
Pump protection system engaged. Release manual fog button, and
press it again to reset pump pro-
tection system.