TECshow NEBULA ZOOM Скачать руководство пользователя страница 2

1. Safety Instructions

Please keep this User Guide for future consultation. If you sell 
the unit to another user, be sure that they also receive this 
instruction booklet.

• 

Unpack and check carefully there is no transportation 
damage before using the unit.

• 

Before  operating,  ensure  that  the  voltage  and  fre-
quency  of  power  supply  match  the power require-
ments of the unit.

• 

It’s  important  to  ground  the  yellow/green  conductor  
to  earth  in  order  to  avoid  electric shock.

• 

The unit is for indoor use only. Use only in a dry location.

• 

The  unit  must  be  installed  in  a  location  with  ade-
quate  ventilation,  at  least  50cm  from adjacent surfac-
es. Be sure that no ventilation slots are blocked.

• 

Disconnect main power before replacement or servicing.

• 

Make sure there are no flammable materials close to the 
unit while operating as it is fire hazard.

• 

Use safety cable when fixes this unit. DO NOT handle the 

unit by taking its head only, but always by taking its base.

• 

Maximum ambient temperature is Ta: 40ºC. DO NOT op

-

erate it where the temperature is higher than this Unit 

surface  temperature  may  reach  up  to  85ºC.  DO  NOT 

touch the housing bare-hand during its operation. Turn 

off the power and allow about 15 minutes for the unit to 

cool down before replacing or serving.

• 

In the event of serious operating problem, stop using the 
unit immediately.Never try to repair the unit by yourself. 
Repairs carried out by unskilled people can lead to dam-
age or malfunction. Please contact the nearest autho-

rized technical assistance center. Always use the same 

type spare parts.

• 

DO NOT touch any wire during operation as high voltage 
might be causing electric shock.

Warning:

To prevent or reduce the risk of electrical shock or fire, do not 
expose the unit to rain or moisture.
DO NOT open the unit within five minutes after switching off.

The  housing,  the  lenses,  or  the  ultraviolet  filter  must  be  

replaced  if  they  are  visibly damaged.

Caution:

There are no user serviceable parts inside the unit. DO NOT 

open the housing or attempt any repairs yourself. In the un-
likely event your unit may require service, please contact 
your nearest dealer.

Installation:

The unit should be mounted via its screw holes on the brack-

et. Always ensure that the unit is  firmly  fixed  to  avoid  vibra

-

tion  and  slipping  while  operating.  And  make  sure  that  the 
structure to which you are attaching the unit is secure and is 

able to support a weight of 10 times of the unit’s weight. Also 
always use a safety cable that can hold 12 times of the weight 
of the unit when installing the fixture.
The equipment must be fixed by professionals. And it must 
be fixed at a place where is out of the touch of people.

p. 2

NEBULA ZOOM 

ENGLISH VERSION

Содержание NEBULA ZOOM

Страница 1: ...USER MANUAL MANUAL DE USUARIO PLEASE READ THE INSTRUCTIONS CAREFULLY BEFORE USE POR FAVOR LEA LAS INSTRUCCIÓNES ANTES DE USAR ZOOM LED Par with zoom 3 x 4 in 1 RGBW 15W LEDs ...

Страница 2: ...g or serving In the event of serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to dam age or malfunction Please contact the nearest autho rized technical assistance center Always use the same type spare parts DO NOT touch any wire during operation as high voltage might be causing electric shock Warnin...

Страница 3: ...s Weight 3 5Kgs Control DMX Channel 8 12Channel ControlModes DMX512 AutoRun Master Slaver Musicmode Construction Display Digital Display Data In Out socket 3 pin 5 pin XLR sockets Power Socket IEC socket Protection Rating IP20 Features Motorized liner zoom system zoom range 6 5 60 Dimmer 0 100 smooth dimming Fast quiet operation and flicker free p 3 NEBULA ZOOM ENGLISH VERSION ...

Страница 4: ... MENU To select the programming functions DOWN To go backward in the selected functions UP To go forward in the selected functions ENTER To confirm the selected functions Set DMX Address Code 1 Press Menu to Set DMX Address and press ENTER keys to enter into 2 Show Set DMX Address DMX Address 001 Press the UP and DOWN keys to amended 3 Press ENTER keys to save and Exit Press the MENU Keys does not...

Страница 5: ...Menu p 5 NEBULA ZOOM ENGLISH VERSION ...

Страница 6: ...dual changing 1 201 255 Color gradual changing 2 9 Speed of color changing Color jump change fade set the speed of CH8 10 Built in effect 0 10 Enable other channels 11 120 Built in effect fast run 121 244 Built in effect slow run 245 255 Music mode 11 Built in effect speed set Built in effect speed asjustable 12 Reset 150 200 rest CH Function Detail 1 Dimmer 0 255 0 100 dimming 2 Strobe 1 255 Stro...

Страница 7: ... controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C One of the channels is not working well 1 The stepper motor might be damaged or the cable con nected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 5 Fixture Cleaning The cleaning of internal and external optical l...

Страница 8: ... se enfríe antes de realizar cualquier tipo de mantenimiento Si el equipo no funciona correctamente interrumpa su uso de inmediato Bajo ninguna circunstancia intente reparar el equipo por su cuenta Las reparaciones re alizadas por personas no calificadas pueden dañar el equipo de forma permanente Pónganse en contacto con el fabricante Siempre utilice piezas de repuesto del mismo tipo Para evitar e...

Страница 9: ...x14x16cm Peso neto 3Kgs Peso bruto 3 5Kgs Control Canales DMX 8 1 Modos de control DMX512 automático maestro esclavo audiorítmico Estructura Pantalla Digital Entrada de data in data out conectores XLR 3 y XLR 5 Tomacorrientes Enchufe IEC Grado de protección IP20 Características Ángulo de zoom 6 5 60 Dimmer Dimming suave 0 100 De funcionamiento veloz silencioso y sin parpadeo ...

Страница 10: ...3 Señal positiva Referencias de la imagen COMMON COMU N DMX DMX DMX DMX DMX512 OUT 3 PIN XLR SALIDA DMX512 de conector XLR 3 DMX512 IN 3 PIN XLR ENTRADA DMX512 de conector XLR 3 Referencias de la imagen XLR Male Socket Conector macho XLR 1 Ground 1 A tierra 2 Cold 2 Frío 3 Hot SALIDA DMX512 de conector XLR 3 Referencia de la imagen Figura 2 Configuración de las clavijas XLR Clavija 1 A tierra Clav...

Страница 11: ...nfirma la selección Configuración de la dirección DMX 1 Seleccione la opción MENU hasta visualizar Set DMX Ad dress y luego presione ENTER 2 Verá en pantalla Set DMX Address DMX Address 001 Utilice las opciones UP y DOWN para modificar la dirección DMX 3 Para guardar los cambios y salir oprima ENTER Para salir sin guardar oprima MENU Descripción del menú ...

Страница 12: ... 2 9 Velocidad del cambio de color Salto de color fade configurar velocidad del canal 8 10 Efectos incorporados 0 10 Habilita otros canales 11 120 Efecto incorporado modo rápido 121 244 Efecto incorporado modo lento 245 255 Modo audiorítmico 11 Efectos incorporados configuración de velocidad Efecto incorporado velocidad ajustable 12 Reset 150 200 Restablecer valores originales Canal Función Descri...

Страница 13: ...eden generar interferencias o daños en la señal C Uno de lo canales no funciona correct amente 1 Es posible que se haya averiado el motor paso a paso o el cable conectado a la placa de circuito impreso 2 El circuito integrado del motor del equipo está dañado 5 Limpieza y mantenimiento Se recomienda la limpieza regular de las partes internas y externas del equipo para optimizar la salida de luz La ...

Страница 14: ...tecshow amproweb com ...

Отзывы: