Trouble Shooting
Maintenance
English version
Problems
Possible reasons
Checking or solutions
Device not power up
Powercon or power cable damaged
Faulty power supply
Change a good power cable to try
Replace new power supply
Pan/Tilt error or vibrate
Faulty Pan/Tilt PCB
Faulty opto sensor
Cable loosen
Replace PT001 PCB
Replace opto sensor OP001
Check the cable connect to OP001
LED off
Temperature protection
Fan not working
Faulty LED
Dimmer and strobe set at 0
Faulty power supply
Check the temperature from menu
Check the fan speed info from menu
Replace new LED
Set dimmer and strobe channel at 255
Replace new power supply
Device not response
to DMX
Faulty communication IC
Faulty display PCB
Wrong DMX addressing
Faulty DMX cable
Replace the IC with back-up one in the
display PCB
Replace new display PCB
Check the address and setting
Change to a good DMX cable