Features:

 

Standard Accessories:

 

 

 

3¾ digit display 
with bargraph

 

 

 Soft 

Carrying 

Case

 

 13 

measurement 

functions, including 
Crest Factor

 

 Instruction 

Manual

 

 True 

RMS 

and 

Average AC 
Measurements up 
to 1000A, 350kW, 
and 600V

 

 

Four AAA Batteries

 

 Data/Min/Max 

Hold 

Function

 

 Test 

Leads

 

 

3 Year Warranty, 
CE mark

 

 
 
 
 
 

General Specifications:

 

Display 

0.8" digit LCD; 2/sec update rate 
42 Segment Bargraph; 20/sec update rate 
Max reading of 3500 
Auto Power Off 

 

Range Selection 

Auto / Manual  

Operation Function 

Min / Max / Data hold button 

Zero (Relative) button 

Surge mode for inrush current measurement 

Crest Factor measurement mode 

TRMS / Average AC selectable 

 

Jaw Opening 

57mm 

Battery Life 

500 hours 

Overrange 
Indication 

Most significant digit blinks 

Low Battery 
Indication 

Icon blinks 

Accuracy Assurance 
Temperature Range 

18~28ºC, 75% R.H. 

Operating 
Temperature 

0~50ºC, <70% R.H. 

Содержание DPM 035

Страница 1: ...n handle just about any measurement application look no further than the DPM 035 This clamp style multimeter can handle your most demanding AC and DC measurements and has great featues like a large display for easy readability and a unique surge mode for measuring in rush current ...

Страница 2: ...splay 0 8 digit LCD 2 sec update rate 42 Segment Bargraph 20 sec update rate Max reading of 3500 Auto Power Off Range Selection Auto Manual Operation Function Min Max Data hold button Zero Relative button Surge mode for inrush current measurement Crest Factor measurement mode TRMS Average AC selectable Jaw Opening 57mm Battery Life 500 hours Overrange Indication Most significant digit blinks Low B...

Страница 3: ...er V x A 3 5kVAR 1VAR 35kVAR 10VAR 350kVAR 100VAR 2 0 rdg 5dgt 1200A overload protection Function Reactive Power V x A x SinØ 3 5kVAR 1VAR 35kVAR 10VAR 350kVAR 100VAR 2 0 rdg 5dgt 1200A overload protection Function Power Factor CosØ 3 5kW 1W 35kW 10W 350kW 100W 3 0 rdg 5dgt 1200A overload protection Function Crest Factor up to 6 1 select range 3 0 rdg 2dgt 1200A overload protection Function ACA 35...

Страница 4: ...y Function DCA 35A 10mA 350A 100mA 1 0 rdg 5dgt 1000A 1A 1 0 rdg 15dgt 1200A overload protection Function DCV 350V 100mV 600V 1V 1 0 rdg 5dgt 10M Input Impedance Function 35 0 01 350 0 1 3 5k 1 1 0 rdg 2dgt 400VDC or 400VAC RMS Overload Protection Function Continuity Test Threshold 30 ...

Отзывы: