TECO TPO47CFAM Скачать руководство пользователя страница 4

Inside you will find many helpful hints on how to use and maintain your air conditioner
properly. Just a little preventive care on your part can save you a great deal of time 
and money over the life of your air conditioner. You'll find many answers to common 
problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting 
Tips first, you may not need to call for service at all.

This appliance is not intended for use by persons (including children) with reduced

 

   

physical ,sensory or mental capabilities or lack of experience and knowledge, unless

 

they have been given supervision or instruction concerning use of the appliance by 
a

 

person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance. 
If the supply cord is damaged, it must be replaced by the manufacturer, its service 
agent or similarly qualified persons in order to avoid a hazard.

The appliance must be installed in conformity with local and regulating electrical 

equipment and installations.

Before operation, please confirm whether power specification complies with that on 

nameplate.
Please make sure connected to properly grounded power outlet.

Do not operate your air conditioner in a wet room such as a bathroom or laundry

.

The appliance with electric heater shall have at

 

l east 1 meter space

 

to

 

the 

combustible

 

materials.

Contact

 

the authorised service technician for repair or maintenance of this unit.

If the air conditioner is knocked over during use, turn off the unit and unplug it from 
the main power supply immediately. Visually inspect the unit to ensure there is no 
damage.
In a thunderstorm, the power must be cut off to avoid damage to the machine due to    
lightning.
To reduce the risk of fire or electric shock, do not use this 

air conditioner

 with any 

solid-state speed control device.

Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or 
similar coverings. Do not route cord under furniture or appliances. Arrange cord 
away from traffic area and where it will not be tripped over.

Before cleaning or maintaining the air conditioner, please turn off air conditioner and 

pull out the power plug.
If the appliance requires repair, contact the TECO National Service Centre. Repairs 

carried out by unauthorised personnel may be dangerous and warranty may be 

voided.

Read This Manual

2

SAFETY PRECAUTIONS

CAUTION

Содержание TPO47CFAM

Страница 1: ...is manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference The design and specifications are subject to change without prior n...

Страница 2: ...FEATURES CARE AND MAINTENANCE TROUBLESHOOTING TIPS OPERATING INSTRUCTIONS INSTALLATION INSTRUCTIONS IDENTIFICATION OF PARTS The rating data indicated on the energy label is based on the testing condi...

Страница 3: ...ON WARNING CAUTION DANGER NOTICE Safety of Children Young children should be supervised to ensure that they do not play with the appliance Packing e g wraps polystyrene etc can be dangerous for childr...

Страница 4: ...ion complies with that on nameplate Please make sure connected to properly grounded power outlet Do not operate your air conditioner in a wet room such as a bathroom or laundry The appliance with elec...

Страница 5: ...er use the plug to start and stop the unit Do not cover or obstruct the inlet or outlet grilles Do not use hazardous chemicals to clean or come into contact with the unit Do not use the unit in the pr...

Страница 6: ...allation instructions for their usage NOTE Optional parts some models without All the illustrations in this manual are for explanation purpose only Your air conditioner may be slightly different The a...

Страница 7: ...Upper air intake 12 Fig 1 13 1 2 4 Fig 2 5 7 9 8 15 14 13 12 5 Upper air filter Behind the grille 6 10 11 Air outlet Drain outlet only for Pump heating model Power cord outlet Power cord buckle Used o...

Страница 8: ...ed to initiate the Auto swing feature When the operation is ON press the SWING button can stop the louver at the desired angle Power switch on off SLEEP ECO button Used to initiate the SLEEP operation...

Страница 9: ...location Press the MODE button until the FAN indicator light comes on Press the FAN SPEED button to choose the fan speed The temperature cannot be adjusted Do not put the duct to window TIMER operatio...

Страница 10: ...d it can not be restarted operation in the first 3 minutes This is to protect the unit Operation will automatically start after 3 minutes Air flow direction adjustment The louver can be adjusted autom...

Страница 11: ...e most comfortable temperature and save energy This function is available on COOL HEAT or AUTO mode only NOTE Not applicable for this model NOTE You can not switch the fan speed in AUTO or DRY mode Op...

Страница 12: ...ress will increase the auto timed setting in 30 minutes increments When the setting time displays 10 0 each press will increase the auto timed setting 60 minutes increments To cancel the auto timed pr...

Страница 13: ...f the unit Allow 30cm to 100cm of space from the wall with for efficient air conditioning Window Kit Installation Your window slider kit has been designed to fit most standard Vertical and horizontal...

Страница 14: ...width of window is less than 26 5 inches Open the window sash and place the window slider kit on the window stool Fig 9 3 Cut the foam seal adhesive type to the proper length and attach it on the top...

Страница 15: ...w sash and place the window slider kit on the window stool See Fig 13 3 Cut the foam seal adhesive type to the proper length and attach it on the top of the window Shown as in Fig 14 4 Close the slidi...

Страница 16: ...or installation IMPORTANT DO NOT OVER BEND THE EXHAUST HOSE SEE Fig 19 14 Fig 16a Fig 17 Fig 19 The exhaust hose can be installed into the wall Not applicable to the units without adaptor A expansion...

Страница 17: ...in hose to the hole Place the open end of the hose adaptor directly over the drain area in your basement floor Please refer to Fig 20b When the water level of the bottom tray reaches a predetermined l...

Страница 18: ...FAN mode for half a day in a warm room to dry the appliance inside and prevent mold forming Stop the appliance and unplug it wrapped the cord and bundle it with the tape Fig 25 Remove the batteries f...

Страница 19: ...mes from the flowing of the refrigerant inside the air conditioner 4 Noisy or vibration 5 Gurgling sound Switch on again after the unit has cool down The automatic over heat protection function When t...

Страница 20: ...Service on 1300 660 037 8 30am 4pm Mon Fri AEST For warranty details please visit www teco com au Service Email had service teco com au Spare Parts had parts teco com au REPAIRS SERVICE WARRANTY 18 If...

Страница 21: ...ge also includes Top Load Clothes Washers Front Load Clothes Washers Auto Sensing Vented Clothes Dryers Refrigerators Chest and Vertical Freezers Bar Fridges Televisions Air Curtains Air Conditioners...

Страница 22: ...www teco com au IBH V1...

Отзывы: