TECO TPO47CFAM Скачать руководство пользователя страница 1

PORTABLE AIR CONDITIONER

Owner’s Manual

IMPORTANT NOTE:

Thank you for selecting a TECO quality Air Conditioner. Read this manual 

carefully before installing or operating your new air conditioning unit. Make 

sure to save this manual for future reference.

The  design  and  specifications  are  subject  to  change without  prior 

notice  for  product  improvement.  Consult  with  the  sales  agency  or 

manufacturer for details.

Model: 

TPO47CFAM

(Cooling Only)

Содержание TPO47CFAM

Страница 1: ...is manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference The design and specifications are subject to change without prior n...

Страница 2: ...FEATURES CARE AND MAINTENANCE TROUBLESHOOTING TIPS OPERATING INSTRUCTIONS INSTALLATION INSTRUCTIONS IDENTIFICATION OF PARTS The rating data indicated on the energy label is based on the testing condi...

Страница 3: ...ON WARNING CAUTION DANGER NOTICE Safety of Children Young children should be supervised to ensure that they do not play with the appliance Packing e g wraps polystyrene etc can be dangerous for childr...

Страница 4: ...ion complies with that on nameplate Please make sure connected to properly grounded power outlet Do not operate your air conditioner in a wet room such as a bathroom or laundry The appliance with elec...

Страница 5: ...er use the plug to start and stop the unit Do not cover or obstruct the inlet or outlet grilles Do not use hazardous chemicals to clean or come into contact with the unit Do not use the unit in the pr...

Страница 6: ...allation instructions for their usage NOTE Optional parts some models without All the illustrations in this manual are for explanation purpose only Your air conditioner may be slightly different The a...

Страница 7: ...Upper air intake 12 Fig 1 13 1 2 4 Fig 2 5 7 9 8 15 14 13 12 5 Upper air filter Behind the grille 6 10 11 Air outlet Drain outlet only for Pump heating model Power cord outlet Power cord buckle Used o...

Страница 8: ...ed to initiate the Auto swing feature When the operation is ON press the SWING button can stop the louver at the desired angle Power switch on off SLEEP ECO button Used to initiate the SLEEP operation...

Страница 9: ...location Press the MODE button until the FAN indicator light comes on Press the FAN SPEED button to choose the fan speed The temperature cannot be adjusted Do not put the duct to window TIMER operatio...

Страница 10: ...d it can not be restarted operation in the first 3 minutes This is to protect the unit Operation will automatically start after 3 minutes Air flow direction adjustment The louver can be adjusted autom...

Страница 11: ...e most comfortable temperature and save energy This function is available on COOL HEAT or AUTO mode only NOTE Not applicable for this model NOTE You can not switch the fan speed in AUTO or DRY mode Op...

Страница 12: ...ress will increase the auto timed setting in 30 minutes increments When the setting time displays 10 0 each press will increase the auto timed setting 60 minutes increments To cancel the auto timed pr...

Страница 13: ...f the unit Allow 30cm to 100cm of space from the wall with for efficient air conditioning Window Kit Installation Your window slider kit has been designed to fit most standard Vertical and horizontal...

Страница 14: ...width of window is less than 26 5 inches Open the window sash and place the window slider kit on the window stool Fig 9 3 Cut the foam seal adhesive type to the proper length and attach it on the top...

Страница 15: ...w sash and place the window slider kit on the window stool See Fig 13 3 Cut the foam seal adhesive type to the proper length and attach it on the top of the window Shown as in Fig 14 4 Close the slidi...

Страница 16: ...or installation IMPORTANT DO NOT OVER BEND THE EXHAUST HOSE SEE Fig 19 14 Fig 16a Fig 17 Fig 19 The exhaust hose can be installed into the wall Not applicable to the units without adaptor A expansion...

Страница 17: ...in hose to the hole Place the open end of the hose adaptor directly over the drain area in your basement floor Please refer to Fig 20b When the water level of the bottom tray reaches a predetermined l...

Страница 18: ...FAN mode for half a day in a warm room to dry the appliance inside and prevent mold forming Stop the appliance and unplug it wrapped the cord and bundle it with the tape Fig 25 Remove the batteries f...

Страница 19: ...mes from the flowing of the refrigerant inside the air conditioner 4 Noisy or vibration 5 Gurgling sound Switch on again after the unit has cool down The automatic over heat protection function When t...

Страница 20: ...Service on 1300 660 037 8 30am 4pm Mon Fri AEST For warranty details please visit www teco com au Service Email had service teco com au Spare Parts had parts teco com au REPAIRS SERVICE WARRANTY 18 If...

Страница 21: ...ge also includes Top Load Clothes Washers Front Load Clothes Washers Auto Sensing Vented Clothes Dryers Refrigerators Chest and Vertical Freezers Bar Fridges Televisions Air Curtains Air Conditioners...

Страница 22: ...www teco com au IBH V1...