Performance Data 240 Volt, 50 Hz, Capacitor Start Run (MY series) 

4 Pole – 1500 RPM

 

Rated 

Power 

(kW) 

Frame 

Size 

Current 

(Amps) 

I

N

 

Speed 

(RPM) 

Efficiency

(%) 

Power 

Factor 

(p.u.) 

Starting 

Torque 

T

   

st

 

T

N

 

Break-

down 

Torque 

T

b

 

T

N

 

Starting 

Current 

I

st

 

I

N

 

 

Approx 

net 

Weight 
IM1001 

Kg 

0.37 71 2.7 1400  62  0.92 0.35 1.7  3.4  7 
0.55 

80 

3.9 

1400 

64 

0.92 

0.35 

1.7 

3.5 

9.5 

0.75 80 5.0 1400  68  0.92 0.32 1.7  3.7  10 

1.1 

90S 

6.8 

1400 

71 

0.95 

0.32 

1.7 

4.0 

13   

1.5 90L 9.0 1400  73  0.95 0.3 1.7 4.6  16 

 
 

Dimensions: Capacitor Start Run (MY series) 

 

 

Bolt on feet – Multi-mount construction 

 

 

 

 

 

TECO Australia Pty. Ltd. 

www.teco.com.au        email: [email protected]

 

 

Sydney Head Office: 335-337 Woodpark Road, Smithfield, NSW 2164  Tel: 02 - 9765 8118  Fax: 02 - 9604 9330 
Brisbane Office: 50 Murdoch Circuit, Acacia Ridge, QLD 4110   

Tel: 07 - 3373 9600  Fax: 07 - 3373 9699 

Melbourne Office: 16 Longstaff Road, Bayswater, VIC 3153 

 

Tel: 03 - 9720 4411  Fax: 03 - 9720 5355  

Perth Office: 28 Belgravia Street, Belmont, WA 6104   

 

Tel: 08 - 9479 4879  Fax: 08 - 9478 3876

 

 

TECO New Zealand Pty. Ltd.: Unit 3, 477 Great South Road, Penrose, Auckland 
 

 

 

 

 

 

 

 

Tel: 64 - 9 - 526 8480 Fax: 64 - 9 - 526 8484

 

MON SP MM MkII-112004 

Содержание MONARCH ML Series

Страница 1: ...MONARCH Single Phase Induction Motors 0 18 kW to 3 kW MON SP Mk II 042004 TECO Australia Pty Ltd...

Страница 2: ...esigned in such a way that vibration is avoided when the motor and the driven machine are running coupled Care should be taken to ensure that any condensate drain plugs are located at the lowest point...

Страница 3: ...ECTION ANTI CLOCKWISE DIRECTION V2 Z2 U2 V2 U1 V1 Z1 U1 V1 Z1 240 VOLTS 240 VOLTS MY ML 1 1 KW AND SMALLER U2 V2 U2 V2 Cs Cs C S Cr C S Cr W2 W3 U3 V3 2 W3 U1 V1 W1 U1 V1 W1 240 VOLTS 240 VOLTS U2 V2...

Страница 4: ...ompany Switch off Switch on No fuse Install fuse Broken wires Check wires and repair Broken lead Check leads and repair Motionless And soundless Faulty winding Check winding and repair Overload trippe...

Страница 5: ...ise Excessive noise Replace the damaged bearing Loose belt sheaf Adjust key and lock the screw Loose coupling Adjust the position of couplings and tighten Loose screw Tighten screw Mechanical noise ca...

Страница 6: ...8 5 7 9 5 1 5 90S 8 7 2800 76 0 95 2 5 1 8 5 8 12 5 2 2 90L 12 5 2800 77 0 95 2 5 1 8 5 8 14 3 100L 16 7 2800 79 0 95 2 5 1 7 6 0 20 5 4 Pole 1500 RPM Rated Power kW Frame Size Current Amps IN Speed...

Страница 7: ...MONARCH SINGLE PHASE INDUCTION MOTORS INSTRUCTIONS FOR HANDLING INSTALLATION AND MAINTENANCE NOTES 7...

Страница 8: ...71 0 95 0 32 1 7 4 0 13 1 5 90L 9 0 1400 73 0 95 0 3 1 7 4 6 16 Dimensions Capacitor Start Run MY series Bolt on feet Multi mount construction TECO Australia Pty Ltd www teco com au email emd teco com...

Отзывы: