Note.

 

When the “Power failure” notification appears, 

it  is  necessary  to  replace  battery  within  one 
week. 

2

  Indication  of  notifications  "Power  failure",  "No 

network",  "Network  search"  is  turned  off  60 
minutes after the siren power up. 

 

 
5 ASSIGNING TO THE SYSTEM 

 

1) 

Remove  the  cover  by  turning  it  counter-

clockwise with respect to the base. 

2) 

Start 

interactive  mode

  from  the  Security 

Hub  mobile  or  desktop  app.  Interactive  mode 
starts for 

60 

sec.

 

3) 

Insert  battery  into  the  siren,  observing  the 

polarity. 

If  4  seconds  after  the  assigning  procedure  start 

the LED indication shows the “No network” indi-
cation,  it  means  that  the  unit  has  been  already 
assigned  to  another  Security  Hub  controller.  In 
this  case,  it  is  necessary  to  reset  the  unit  (see 
Section  6)  and  repeat  the  assigning  procedure 
(steps 2) - 3)). 

 

Before  re-installing  the  battery,  wait  at  least  20 
seconds. 

 
Make  sure  assigning  is  successful  with  Security 
Hub  mobile  or  desktop  app.  If  assigning  is  unsuc-
cessful,  repeat  the  procedure.  Before  re-installing 
the battery, wait at least 20 seconds. 

Note 

–  Setting  of  operating  frequency  is  auto-

matic. 

 

ATTENTION! 

 

It is forbidden to simultaneously start assigning 

procedure on several radio devices. 

 
6 DE-ASSIGNING AND RESET  

 

 

The  siren  is  de-assigning  using  Security 

Hub mobile or desktop app. 

 

Reset procedure

1) 

Remove  the  cover  by  turning  it  counter-

clockwise with respect to the base. 

2) 

Close

 Del 

contacts on the PCB

.

 

LED indica-

tor switches on.

 

3) 

After  the  LED  indicator  switches  off,  open 

Del 

contacts.  

4) 

The siren will form “No Network” LED notifi-

cation  and  become  ready  for  assigning  in  an-
other controller.  

 

 
7 INSTALLATION PLACE 

 

 

The  siren  can  be  installed  both  on  the  wall  and 

on the ceiling.  

  Prevent from direct sunlight exposure. 

  Siren is not recommended to install: 

- on massive metal structures or closer than 1m 

from them; 

-  closer  than  1  m  from  power  lines  and  metal 

water  or  gas  pipes,  sources  of  radio  interfer-
ence; 

- inside metal structures.

 

 

 

 
8 INSTALLATION PROCEDURE 

 

 

1) 

Remove  the  cover  by  turning  it  counterclock-

wise with respect to the base. Remove PCB.

 

 

2) 

Make markup at the selected installation surface 

using the base as a template. 

 

 

3) 

Conduct  wires  of  external  power  supply  (not 

required  when  supplied  from  battery)  through  the 
holes for wire entry. 

4) 

Fix the base on the bearing surface 

5) 

Install the siren

’s PCB. 

 

 

 
ATTENTION!

  

When  connecting  an  ex-
ternal  12  V  power  supply, 
the  location  of  the  wires 
should  be  as  shown  on 
the figure!  

 

 

6) 

Insert battery, observing polarity. 

 

7) 

Close  the  siren  cover  by  placing  it  on  the  base 

and turning it clockwise until it stops. 

 

Note 

–  When  external  power  source  12V  is  con-

nected,  the  siren  automatically  switches  to  supply 
from  it,  when  disconnected  -  it  switches  to  battery 
supply.

 

 

ATTENTION! 

Due  to  the  peculiarity  of  signal 

transmission  over  the  radio  channel  there  may 
be  a  short  delay  before  siren  is  switched  on  by 
the  command  from  Security  Hub controller.  The 
delay time depends on the workload of the radio 
channel and the noise situation at the facility.

 

 

9 WARRANTY 

The  warranty  period  is  5  years from  the  date  of 
manufacture

,  which  is  indicated  on  device’s 

housing and box. 

 
Holes for wire entry 

Mounting 
holes 

Отзывы: